LP Gas Orifice Spud Chart for TripleTier
Burner Location
Burner Rating
Left front (external
11,800 Btu/h
TripleTier
®
burner)
Left front (internal
2,200 Btu/h
®
TripleTier
burner)
7. Replace burner plate, head and cap.
8. Place Natural gas orifice spuds in plastic parts bag for future
use and keep with literature package.
9. Reinstall the warming drawer. See the "Replace Oven Racks
& Warming Drawer" section for instructions.
10. Complete installation. See "Make Gas Connection" and
"Electronic Ignition System" sections.
Checking for proper cooktop burner flames is very important.
The small inner cone should have a very distinct blue flame
¼" to ½" long. The outer cone is not as distinct as the inner
cone. LP gas flames have a slightly yellow tip.
IMPORTANT: You may have to adjust the "LO" setting for
each cooktop burner.
Natural Gas Conversion
WARNING
Tip Over Hazard
A child or adult can tip the range and be killed.
Connect anti-tip bracket to rear range foot.
Reconnect the anti-tip bracket, if the range is moved.
Failure to follow these instructions can result in death
or serious burns to children and adults.
To Convert Gas Pressure Regulator
1. Turn manual shutoff valve to the "closed" position.
2. Unplug range or disconnect power
A
A. To range
B. Manual shutoff valve "closed" position
C. Gas supply line
3. Remove warming drawer. See the "Remove Warming
Drawer" section for instructions. Locate gas pressure
regulator at rear of warming drawer compartment.
®
Flame Burners
Color
Size
Brown
1.00 mm
Orange
0.42 mm
B
C
4. Remove access cover from the gas pressure regulator.
A
A. Gas pressure regulator
IMPORTANT: Do not remove the gas pressure regulator.
Gas pressure regulator
5. Remove the access cap by using a wrench, turning the
access cap counterclockwise.
6. Remove spring retainer from the cap by pushing against the
flat side of the spring retainer. Look at the spring retainer to
locate the "LP" or "NAT" position.
7. Turn over the spring retainer so the "NAT" is showing on the
bottom.
8. Snap the spring retainer back into the cap.
9. Reinstall the cap onto the regulator.
E
D
A. Access cap
B. Gasket
C. Gas pressure regulator
To Convert Standard Surface Burners
1. Remove burner cap.
®
2. Using a T20 TORX
screwdriver, remove the burner base.
3. Apply masking tape to the end of a 7 mm nut driver to help
hold the gas orifice spud in the nut driver while changing it.
Press nut driver down onto the gas orifice spud and remove
by turning it counterclockwise and lifting out, set gas orifice
spud aside.
A
B
A. Igniter electrode
B. Gas tube opening
C. Burner cap
D. Burner base
A
B
C
D. Spring retainer
NAT position
E. Spring retainer
LP position
C
D
21