Check the engine oil level before each use or every 8
hours of operation.
1. Place the generator on a level surface and allow the
engine to cool for several minutes.
2. Remove the oil dipstick and wipe the dipstick clean.
3. Insert, then remove the oil dipstick.
Acceptable Oil Level – On the flat side of the dipstick, oil
is visible up to the first notch.
Low Oil – Oil is below the first notch on the dipstick
4. If low, remove the oil fill cap and add the recommended
engine oil incrementally and recheck until the level is at
the top notch on the dipstick. DO NOT overfill. If over the
top notch on the dipstick, drain the oil to reduce the oil
level to the full mark.
5. Replace the oil dipstick and oil fill cap.
ENGINE OIL CHANGE
When using the generator in dusty conditions or extremely
hot weather, change the oil more frequently. Change the
oil while the engine is still warm from operation.
1. Place the generator on a level surface and allow the
engine to cool for several minutes.
2. With a damp rag, clean around the oil fill cap. Remove
the oil fill cap.
3. Place an oil pan (or suitable container) under the oil
drain.
MAINTENANCE
4. Remove oil drain bolt and allow the oil the to drain.
5. Replace oil drain bolt.
6.
by rotating it counterclockwise. Allow the oil to drain
the engine.
7. Apply clean oil to the rubber seal on the new oil filter.
Install by hand, turning clockwise until the seal contacts
the engine then turn another 3/4 turn. DO NOT over
tighten.
8. Fill with the recommended oil. Stop frequently to check
the oil level. Do not overfill. If the engine is overfilled,
the excess oil may get transferred to the air cleaner
housing and air filter. An indication of overfilling is white
or blue smoke coming from the muffler when the engine
is running.
Maximum oil capacity: 1.7 Quart (1.6 Liter)
9. Install the oil dipstick. Screw in the oil fill cap securely.