WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A
PARTICULAR PURPOSE) AND OF ALL OTHER OBLIGATIONS
OR LIABILITIES ON THE PART OF DSC. DSC MAKES NO
OTHER WARRANTIES. DSC NEITHER ASSUMES NOR
AUTHORIZES ANY OTHER PERSON PURPORTING TO ACT ON
ITS BEHALF TO MOD8IFY OR TO CHANGE THIS WARRANTY,
NOR TO ASSUME FOR IT ANY OTHER WARRANTY OR
LIABILITY CONCERNING THIS SOFTWARE PRODUCT.
EXCLUSIVE REMEDY AND LIMITATION OF WARRANTY -
UNDER NO CIRCUMSTANCES SHALL DSC BE LIABLE FOR
ANY SPECIAL, INCIDENTAL, CONSEQUENTIAL OR INDIRECT
DAMAGES BASED UPON BREACH OF WARRANTY, BREACH
OF CONTRACT, NEGLIGENCE, STRICT LIABILITY, OR ANY
OTHER LEGAL THEORY. SUCH DAMAGES INCLUDE, BUT ARE
NOT LIMITED TO, LOSS OF PROFITS, LOSS OF THE SOFTWARE
PRODUCT OR ANY ASSOCIATED EQUIPMENT, COST OF
CAPITAL, COST OF SUBSTITUTE OR REPLACEMENT
EQUIPMENT, FACILITIES OR SERVICES, DOWN TIME,
PURCHASERS TIME, THE CLAIMS OF THIRD PARTIES,
INCLUDING CUSTOMERS, AND INJURY TO PROPERTY.
DSC recommends that the entire system be completely tested on a reg-
ular basis. However, despite frequent testing, and due to, but not limited
to, criminal tampering or electrical disruption, it is possible for this
SOFTWARE PRODUCT to fail to perform as expected.
Regulatory Information
Notes for EN50131-1:2006/A1:2009 Compliant installations:
Model TL8803GI-EU is an SPT Type X - the module is self-contained
within its own housing and it receives power from an external com-
patible CIE or Power Supply source that are in compliance with
EN50131-6:2008.
This product has no replacement parts and no accessible software pro-
grammable options (everything is already pre-programmed).
The TL8803GI-EU connects to compatible DSC alarm control panels
using the DSC proprietary serial interface and protocol PC-Link (con-
verted also to RS-422). The module operates in pass-through mode and
it does acknowledge the alarm to the compatible control panel after an
acknowledgement has been received from the compatible alarm
receiver.
1.
The TL8803GI-EU module is monitored by the control panel and
it is programmed via the programming menu (* 8, section [851]
in the control panel. The interface is connected to the PC-Link
bus as shown in the diagram included in this manual. There is no
monitoring for substitution.
2.
The IP and Cellular path is immune to conducted and radiated
RF fields with levels up to 10V/m as tested per EN50130-4
Standard.
3.
The TL8803GI-EU module conforms with radiated emissions
levels for Class B equipment as per standards EN61000-6-
3/EN55022/CISPR22.
4.
The TL8803GI-EU module uses AES128 encryption and
heartbeat supervision for HSPA 3G Cellular communication
paths and it meets security levels S2 as per EN50136-2:2013. It
also uses authentication for each message exchanged with the
compatible receiver equipment at ARC and it meets level I2 for
information security.
5.
The TL8803GI-EU module has one communication path: HSPA
3G Cellular communication path using 900/1800/2100MHz
Public Cellular Network and one Ethernet path. The
communication paths can be used in a standalone
mode/individual mode or in back-up (fall-back) mode in
conjunction with a DSC alarm system (compatible DSC alarm
control panel models: HS2128/064/032/016). The supported ATS
configuration is: Custom Category C.
6.
The TL8803GI-EU has been tested for compliance in
conjunction with the following applicable standards: EN50131-
1:2006/A1:2009, EN50136-1:2012, EN50136-2:2013,EN50131-
10:2014, ATS configuration: C.
For EN50131-1:2006/A1:2009 compliant installations, the following pro-
gramming options shall be set as described.
Supervision Heartbeat:
· shall be set to 180 seconds
NOTE: The compatible receiver at ARC location shall have super-
vision window programmed for 180 seconds.
TL8803GI-EU has been certified by ALTER TECHNOLOGY TÜV
NORD S.A.U. in accordance with EN50131-1:2006/A1:2009,
EN50131-10:2014 requirements for Grade 3, Class II and EN50136-
2:2013 Configuration: C
SIMPLIFIED EU DECLARATION OF
CONFORMITY
Hereby, Tyco Safety Products Canada Ltd declares that this radio
equipment is in compliance with Directive 2014/53/EU. The full text of
the EU declaration of conformity is available at the following internet
address:
http://dsc.com/pdf/1609001
Frequency bands
Z-wave
868.42 MHz
Image sensor
868.3 MHz
Cellular radio
850/900/2100 MHz bands
European single point of contact
Tyco Safety Products, Voltaweg 20, 6101 XK Echt, Netherlands.
ATS Custom Category C
EN50136-1:2012 Annex D Table
D.1
EN50136-1:2012 Annex D Table
D.2
EN50136-1:2012 Annex D Table
D.3
EN50136-1:2012 Annex D Table
D.4
EN50136-1:2012 Annex D Table
D.5
EN50136-1:2012 Annex D Table
D.6
EN50136-1:2012 Table 1
EN50136-1:2012 Table 4
EN50136-1:2012 Table 5
EN50136-1:2012 Table 6
EN50136-2:2013 Table 1
EN50136-2:2013 Table 2
EN50136-2:2013 Table 3
- 25 -
Maximum power
4 dBm max EIRP
10 dBm max EIRP
30 dBm max EIRP
Level
D3
M3
T4
A4 (Depending on cellular carrier
used)
S1 (use AES-128 and
authentication/sequential
information in each message
transmitted to the SG receiver)
I1 (use AES-128 encryption)
Use single communication path
(cellular network)
ATS failure reported to ARC
ATS failure reported to AS (DCS
compatible control panel
HS2128/HS2064/HS2032/HS2016)
There is no recording of
availability failure
No logging function provided
No memory provided for logging
function
ATS failure reported to ARC