Assembly of the castor mounting fixture (Fig. 4 + 5)
• Turn the stainless steel container (8) upside down
(the machine head (2) must be removed).
• Slide the castor mounting fixtures (5) into the re-
cesses provided on the base (7). (4x)
• Secure the castor mounting fixtures (5) with a
screwdriver (not included) with one screw (20)
each. (4x)
Assembly of the rollers (Fig. 6)
Press the four castors (6) into the holes in the castor
mounting fixtures (5).
Mounting appliance head and handle (Fig. 7)
• Place the appliance head (2) onto the container (9). Se-
cure the appliance head (2) with the locking hooks (4).
When fitting the appliance head (2), make sure that the
locking hook (4) locks into place correctly.
• Place the handle (1) on the appliance head (2) and
secure it with two screws (20) by using a screw-
driver (not included).
Fitting the foamed plastic filter (Fig. 3+8)
Never use the appliance without a filter! Always en-
sure that the filters are correctly mounted
• Fitting the foamed plastic filter (15): For wet-vac-
uuming, slip the supplied foamed plastic filter (15)
over the filter basket with safety float valve (13).
Assembling the paper bag (Fig. 3+9)
For vacuuming fine, dry dirt it is recommended that
you paper bag (16). Slip the paper bag (16) over the
vacuuming hole inside of the container (9). The paper
bag (16) is suitable for dry-vacuuming only. The paper
bag (16) makes it easier to dispose of the sucked-in
dust.
Fitting the suction hose (Fig. 3+10+11)
Connect the suction hose (14) to the corresponding
connector on the wet and dry vacuum cleaner, de-
pending on the application required.
Vacuuming:
Connect the suction hose (14) to the suction hose
connector (10). Therefore push the end of the suction
hose (14) with the two nipples into the suction hose
connector (10) (A). Adjust the two nipples to the re-
cesses. In the final position, turn clockwise (B).
Blowing:
Connect the suction hose (14) to the blow connec-
tor (12). Push the end of the suction hose (14) with
the two nipples into the blow conector (10). Adjust the
two nipples to the recesses. A rotation is not required
here.
Mounting the plastic extension tube (19), hose
and nozzles (17/18) (Fig. 12)
• Put the plastic extension tubes (19) together.
• Connect the composited plastic extension tube to
the curved end of the suction tube (14).
• Mount the floor nozzle (17) or the crevice nozzle
(18) on the composited plastic extension tube.
14 І 32
8. Operation
m WARNING!
Switch off the appliance if liquid or foam is emitted
with the exhaust air when wet vacuum cleaning.
Switching off/on/automatic mode (Fig. 13)
The ON/OFF switch (11) has two settings:
• Switch position 0 : Off
• Switch position I : On
Press the On/Off switch (11) to switch on.
Press the On/Off switch (11) again to switch off.
Dry vacuuming (Fig. 9)
Use the paper bag (16) for dry vacuuming. Always
ensure that the filters are correctly mounted.
Wet vacuuming (Fig. 8)
For wet-vacuuming, use the foamed plastic filter (15).
Ensure that the foamed plastic filter (15) is correctly
mounted.
If the container (9) is full, the safety float valve closes
the suction opening and the suction process is inter-
rupted.
m ATTENTION!
The appliance is not suitable for the vacuuming of
combustible liquids. For wet vacuuming, only use the
supplied foamed plastic filter (15).
Water drain plug (8) (fig. 14)
The stainless steel container (9) is equipped with a
water drain plug (8) in order to make it easier to drain.
Open the water drain plug (8) by turning it counter-
clockwise and drain out the liquid.
9. Maintenance and cleaning
m ATTENTION!
Pull out the power plug before every maintenance
operation. This also includes connecting to the water
supply or trying to eliminate leaks. There is a risk of
electrocution or of injury from moving parts.
Cleaning
It is recommended to clean the appliance after each
use. Never direct the water jet against the appliance,
nor clean the appliance under flowing water. This
could give rise to the danger of electric shock and
damage the appliance!
Empty the container (9) after operation: The absorbed
liquid can be drained after opening the screw cap for
draining liquids (8). There remains a residue of liquid
in the container (9). To remove any residual fluid, re-
move the appliance head (2) from the container (9) by
opening the locking hooks. Pour out the liquid resi-
due. Clean the container with a damp cloth.
• Replace a full paper filter bag
• Always keep the appliance clean. Do not use any
detergents or solvents.