Télécharger Imprimer la page

Pentair JUNG PUMPEN U3K/2 Instructions De Service page 15

Publicité

All manuals and user guides at all-guides.com
Cleaning of the impeller (U5 and U6)
To clean the impeller, and in the event of an
obstacle or blockage, the foot strainer must
be levered off. After this, take out the screws
on the underside of the pump and remove the
cover. The impeller can now be cleaned.
Worn impellers can have sharp edg-
es.
If the pump performance decreases, the im-
peller must be checked for wear and replaced
by the manufacturer if necessary.
Tightening torque M
for A2 screw materials
A
for M 5 M
= 5 Nm
A
for Amtec 3,5
M
=  1 Nm
A
for Amtec 5,0
M
=  2 Nm
A
QUICK TIPS FOR REMEDYING
FAULTS
No pump operation
• Check mains current (do not use a pin
gauge)
• Fuse faulty = may be too weak (please refer
to Electrical Connection)
• Mains supply cable damaged = repair to be
carried out by manufacturer only
Pump runs but does not pump
• Empty the pressure pipe or hose to allow
the non-return valve to open and the air to
escape from the pump housing, it may be
necessary to carry out a ventilation drilling
Impeller blocked
• Solids and fibrous matter have become
lodged in the pump housing = clean
Decreased pumping performance
• Foot strainer obstructed = clean
• Pressure pipe obstructed = clean
• Rotor worn out = repair to be carried out by
the manufacturer
• Wrong direction of rotation (for a three-
phase current) = ask a qualified electrician
to change 2 phases of the supply line
JUNG PUMPEN GmbH - Industriestr. 4-6
33803 Steinhagen, Germany
13
401.10.1307
EN 12050-2:2001
Lifting plant for faecal-free wastewater DN 32
U 3 K (JP00205/2)
U 3 K spez. (JP09562/2)
U 3 KS (JP00206/2)
U 3 K spez. (JP44255)
U 3 KS (JP09808/2)
U 3 KS spez. (JP09563/2)
U 3 KS spez. (JP45195)
Collecting and automatically lifting faecal-free
waste water above the backflow level in buildings
and sites
REACTION TO FIRE
WATERTIGHTNESS
EFFECTIVENESS (LIFTING EFFEC-
TIVENESS)
- Pumping of solids
- Pipe connections
- Ventilation
- Minimum flow velocity
- Minimum free passage of the plant
- Minimum useful volume
MECHANICAL RESISTANCE
- Load bearing capacity and struc-
tural stability of collection tank for
use outside buildings
- Structural stability of collection
tank for use inside buildings
NOISE LEVEL
DURABILITY
- of structural stability
- of lifting effectiveness
- of mechanical resistance
DANGEROUS SUBSTANCES
ENGLISH
0197
U 5 K (JP09386/0)
U 5 KS (JP09387/0)
U 5 KS (JP09417/0)
U 6 K E (JP00226/2)
U 6 K D (JP00228/3)
U 6 K ES (JP00227/2)
U 6 K ES (JP09260/2)
U 6 K DS (JP00229/3)
U 6 K DS (JP09261/3)
A1
Pass
Pass
Pass
NPD
Pass
Pass
NPD
NPD
NPD
≤ 70 dB(A)
NPD
Pass
NPD
NPD
15 15

Publicité

loading