WATER TANKS
⊲ Both water tanks may be removed by pushing the tank toward the back of the oven until you trigger the
click-in/click-out mechanism. The tanks will pop out of the oven case and slide out freely for cleaning and
filling.
⊲ Remove the lid of the water tanks by lifting them directly up. DO NOT lift from one end or the other.
⊲ Gently wash the water tanks and lids with a soft cloth or non-abrasive sponge, warm water, and dish soap.
Rinse and let dry.
DO NOT USE ABRASIVE SPONGES. DO NOT PUT WATER TANKS INSIDE A
DISHWASHER.
⊲ Replace the lid and slide the tank back into the appropriate channel on the left side of the oven. Fill with
distilled water using the fill hole. Push until the click-in mechanism locks it in place.
⊲ Slide the waste water tank back into its channel and push until the click-in mechanism locks in place.
DESCALING
When the steam generator operates, there is a gradual accumulation and deposit of limestone scale inside
the boiler because of calcium contents in the water. This can have a negative effect on the performance of
the boiler, as well as the food quality. Using distilled water slows down this process, but it will still happen. To
prevent scale build up, you will need to periodically descale the oven. You can purchase descaling liquid on
the Anova website or use any generic descaling liquid of your choice.
The Oven will prompt you to descale the oven after 30 hours of steam usage. You can also run the descale
process at any time from the settings. The user interface will guide you through the procedure. The duration
of the complete procedure is about 40 minutes.