When framing in appliance, allow for fi nishing material thickness.
* Minimum combustible side wall clearance
** Does not include fi nishing trim depth
Mandatory top and
bottom enclosure
ventilation required,
see note above.
*
*
*
Mandatory top and
bottom enclosure
ventilation required,
see "framing" section.
note:
Use metal studs wherever non-combustible facing is required.
note:
The appliance enclosure must be provided with suffi cient air circulation to avoid a fi re hazard. Install ventilation
grilles (minimum free air opening of 40 sq. in. [0.03 sq. meters]) at both fl oor and ceiling levels of the enclosure.
These grilles must not restrict the fl ow of heat by more than 25%. Do not install into any area having a height
less than 7 ft. (2m) (ceiling enclosure to appliance bottom, exclusing hearth height). The location of windows,
doors and the traffi c fl ow in the room where the stove is to be located should be considered. If possible, you
should choose a location where the chimney will pass through the house without cutting a fl oor or roof joist.
* Allow for fi nished fl oor and hearth thickness when setting these dimensions.
** When constructing the enclosure allow for fi nishing material thickness to maintain clearances.
Clearances for burning cord wood & vented gas
logs
Maximum mantel depth vs. mantel height
Clearances for unvented gas log set
*maximum 12" mantel depth at any height
above 28 7/16" (72.2cm) from the top of
the faceplate.