Installation
Electrical Connection
WARNING
Disconnect power from the source before starting
this procedure.
The terminal block on the back of the range allows for a
single phase or 3-phase installation. Remove the termi-
nal block cover to expose the screws with corresponding
numbers. Refer to the illustration below. Route the wires
through the strain relief and to the terminal block.
SINGLE PHASE INSTALLATION
1
Connect ground to position one.
2
Connect neutral to position two.
3
Connect L1 to position four.
4
Tighten the screws on the strain relief and install the
terminal block cover.
6
5
4
3
2
1
Single phase
6 | English
9053370A_ICB_WF_IRange_IG_0222.indd 6
9053370A_ICB_WF_IRange_IG_0222.indd 6
3-PHASE INSTALLATION
1
Remove the two metal bridges from positions four, five,
and six. Refer to the illustration below.
2
Connect ground to position one.
Connect neutral to position two.
3
4
Connect L1 to position six.
5
Connect L2 to position five.
6
Connect L3 to position four.
7
Tighten the screws on the strain relief and install the
terminal block cover.
6
5
4
3
2
1
REMOVE
3-phase
Door Alignment
To adjust the door, follow these steps:
1
Remove the skirt by extracting the screws.
2
Open the door, and loosen the nut. Refer to the
illustration below.
Close the door, and turn the screw clockwise to raise
3
and counterclockwise to lower the door.
Open the door, and tighten the nut.
4
5
Close the door, and reinstall the skirt.
ADJUSTMENT
SCREW
NUT
SKIRT
Door alignment
Troubleshooting
IMPORTANT NOTE: If the range does not operate properly,
follow these troubleshooting steps:
•
Verify electrical power is supplied to the range.
•
If the range does not operate properly, contact Wolf
Factory Certified Service. Do not attempt to repair the
range. Wolf is not responsible for service required to
correct a faulty installation.
2/21/22 8:54 AM
2/21/22 8:54 AM