Specifications
Installation Requirements
Follow all minimum clearances to combustible surfaces
shown in the installation illustration.
Electrical Requirements
Installation must comply with all applicable electrical
codes and be properly grounded (earthed).
Locate the electrical supply flush with the wall or floor and
within the shaded area shown in the installation illustration.
A separate circuit servicing only this appliance is required.
If a power supply cord is used, the cord must be desig-
nated for use with ranges and rated for 240 V, 50 amps,
and must include 3 or 4 conductors.
Performance may be compromised if the electrical supply
is less than 240 volts.
REQUIRED POWER SUPPLY
Single phase
220–240 V AC, 50/60 Hz
3-phase
380–415 V AC, 50 Hz
MAXIMUM CONNECTED LOAD
RANGE
SINGLE PHASE
762 mm
50 A
914 mm
60 A
RATING PLATE
Rating plate location
4 | English
9053370A_ICB_WF_IRange_IG_0222.indd 4
9053370A_ICB_WF_IRange_IG_0222.indd 4
IMPORTANT NOTE: Connection of this appliance should
be through a fused connection unit or a suitable isolator,
which complies with national and local safety regulations.
The on/off switch should be easily accessible after the
appliance has been installed. If the switch is not accessible
after installation (depending on country) an additional
means of disconnection must be provided for all poles of
the power supply. When switched off there must be an all
pole contact gap of 3 mm in the isolator switch. This 3 mm
contact disconnect gap must apply to any isolator switch,
fuses and/or relays according to EN60335.
CAUTION
The supply wiring must be protected to withstand
temperatures up to 100°C.
3-PHASE
19 A
28 A
Induction Range
INSTALLATION
330
457
mm
mm
152
mm
914 mm
TO COOKING
SURFACE
ELECTRICAL IN
'A' LOCATION
ONLY
SIDE VIEW
51
mm
*Without ventilation hood, 914 mm minimum clearance countertop to combustible materials.
NOTE: Shaded area above countertop indicates minimum clearance to combustible surfaces,
combustible materials cannot be located within this area.
For island installation, 305 mm minimum clearance back of range to combustible rear wall above countertop.
OPENING WIDTH
W
762 mm Range
762 mm
260 mm
914 mm Range
914 mm
413 mm
762 mm
914 mm
TO
TO BOTTOM OF
*
VENTILATION HOOD
W
OPENING WIDTH
A
216
mm
124
E
mm
FRONT VIEW
A
2/21/22 8:54 AM
2/21/22 8:54 AM