are meant to be utilized for windows and or curtain magnetic contacts.
Zone from 7 to 10 . They have to be connected from the terminal 'M1' to the 'M4' of the CP. They
3.
are all programmed with no delay, double-balance and belonging to the Partition "Volumetric
Detectors". They are meant to be utilized for Volumetric Sensors installed inside the building.
Outputs:
Depending on the Control Panel Model, up to 128 Outputs can be managed contemporarily, linked to the
lares Control Panel, the ergo Keypad (up to 2 Zones per Keypad) and the auxi expansion modules (up to 5
Zones) all these being physical outputs OC (Open Collector) type. Additionally there are logic Ouputs,
which need to be used to activate events on the Bus Sirens (imago and radius). In this template 5 Outputs
have been already programmed as follows:
Relay. It is the only relay Output present on the Panel, whose terminals are available directly on
1.
the lares Control Panel. It has a free contact (C-NC-NO) and one linked directly to +12V (+R, +A). It
activates itself when an alarm condition or a masking event is occurring. It can be used to link
Sirens of "Universal type" or to activate external communication devices.
Arming Status . It is a logic Output which activates the flashing red LEDs on the Outdoor imago
2.
Siren when the system is armed Stay or Away .
Alarm imago : it is a logic Output which activates the Outdoor imago Siren when a condition of
3.
alarm or tamper are occurring.
Alarm radius : it is a logic Output which activates the Indoor radius Siren when a condition of alarm
4.
or tamper are occurring and the System is Armed (AWAY).
Manual Exit : it is a physical Output, associated to the M1 Terminal of the Keypad ergo. It
5.
activates / disactivates when the number 9 will be touched for more then 3 seconds on the
Keypad. It is meant to activate an external automation (automatic gate, door opening, garden
lights, etc.)
BUS Peripherals:
The Control Panel Architecture enables to configure many different Peripherals, whose number depends
from the CP model. In this template, 4 Peripherals have been already programmed as follows:
Nr. 1 ergo Keypad (Ksenia code KSI2100000.300)
1.
Nr. 1 volo Outdoor Proximity Reader (Ksenia code KSI2200000.300Black or KSI2200000.310 in
2.
White color)
Nr. 1 r adius BUS Indoor Siren with Emergency Light Function (Ksenia code KSI6101000.300)
3.
Nr. 1 imago BUS Outdoor Siren (Ksenia code KSI6301000.xxx with various color availability)
4.