7.4

Master/Slave Mode

Notes
The master/slave mode allows for connecting several devices to a single master device in a daisy
chain.
All slave devices will then work synchronously with the master device.
Configure all slave units before connecting the master unit to the daisy chain.
The maximum number of slave units you can connect to a master unit is 18.
Slave units:
1.
Connect the DMX input from your slave device to the DMX output of the previous device in the
chain.
2.
Connect the slave device to the mains to switch it on.
3.
Repeat these steps for all slave units.
Master unit
1.
Connect the master device to the mains to switch it on.
2.
Press MENU to enter the menu.
3.
Set the master unit to work in one of the running modes.
4.
Connect the master unit as the first unit in the chain by connecting the DMX output of the master
device to the DMX input of the first slave unit.
7.5

DMX Mode

The DMX mode allows you to control the device with any universal DMX controller.
All DMX-controlled devices need a digital start address so that the correct device responds to the
signals. This digital start address is the channel number from which the device starts to "listen" to
the DMX controller. The same starting address can be used for a whole group of devices or an
individual address can be set for every device.
When all devices have the same address, all the units will "listen" to the control signal on one
particular channel. In other words: changing the settings of one channel will affect all devices
simultaneously. If you set individual addresses, each device will "listen" to a separate channel
number. Changing the settings of one channel will only affect the device in question.
To set the device to work with a DMX controller:
1.
Press MENU and select the DMX mode.
2.
Select the DMX start address and confirm.
Start addresses
Use the table below to define the correct address. The table shows the settings for units 1 to 3. Apply the
same principle for the other units. Example:
channel mode
24
start address
channel
DMX Channel Values
24-channel mode
channel
function
1
2
V. 01 – 21/01/2016
st
1
unit
1
1 - 24
from
dimmer
000
000
020
025
065
strobe
070
085
090
105
110
HQMH10001
nd
rd
2
unit
3
unit
25 (1 + 24)
49 (25 + 24)
25 - 48
49 - 72
to
description
255
dimmer
019
no function
024
on
064
standard strobe, fast > slow
069
on
084
strobe effect 1, fast > slow
089
on
104
strobe effect 2, fast > slow
109
on
124
strobe effect 3, fast > slow
7
highest start address
489
©Velleman nv