functions, just connect the phase and the neutral wires: the product will work correctly even without the
external programmer.
❑
In bathrooms, kitchens or other humid areas, install the connection terminal at least 25cm off the floor.
❑
The electrical connection to the power supply must also be fitted with a two -pole switch with a minimum gap between
the contacts that allows complete disconnection according to excess voltage III category conditions . As a priority,
always abide you national wiring rules.
❑
It is forbidden to connect the appliance to the earth circuit. DO NOT CONNECT THE PILOT WIRE (BLACK) TO THE
EARTH CIRCUIT.
❑
If the product is powered through a 30mA differential switch, make sure the pilot wire is also controlled by the
differential switch.
L
N
6. Using the product
6.1 Description of controls
A – Switch on/Stand-by
B – Operating mode
C – Special functions
D – Increase / Activate
E – Decrease / Deactivate
F – Display
G – Main switch
6.2 Operating
6.2.1 Switching on the screen
If the screen is not switched on, push any
key to make it light up.
The screen lights up and stays on for 30
seconds after the last time any key is
pushed.
Phase (brown)
Pilot wire (black) – DO NOT CONNECT TO EARTH
Neutral (blue)
A
B
C
D
F
When the screen is switched off, the first
time any key is pushed the screen lights
up
controlled by the key pushed.
22
E
without activating the function
G