Télécharger Imprimer la page

Intex 128452EX Manuel Du Propriétaire page 32

Masquer les pouces Voir aussi pour 128452EX:

Publicité

TROUBLESHOOTING (continued)
PROBLEM
TUB LOSES AIR
• Air valve cap loose.
PRESSURE
• Air valve base loose.
• Hole, cut or split on spa tub.
• Air passage selection dial is not in
the "
LEAKING BETWEEN
• Spa control base inlet/outlet
SPA TUB
connections not securely tight.
CONNECTORS AND
• Spa control base inlet/outlet o-ring
CONTROL UNIT
missing/dirty.
CONNECTORS
SPA IS TOO NOISY
• Control base components not
IN FILTRATION
securely attached.
MODE ONLY
• Control base ground not level and
fi rm.
• Spa fi lter motor failed.
INSUFFICIENT
• Insuffi cient operating time of the
CHLORINE
sanitation system and/or heater is
running at the same time.
• Chlorine loss due to intense sunlight
exposure.
• The bather load has increased.
• Clogged or dirty electrolytic cell.
AIR PRESSURE
• Hose adaptor o-ring missing.
IS WEAK DURING
• Infl ation hose adaptor not securely
INFLATION
tighten.
• Connection between the hose
adaptor and blower infl ation outlet,
and between the infl ation hose and
infl ation valve are loose.
• Air blower failure.
AIR BUBBLES ARE
• O-ring missing between the control
NOT AS STRONG
base air outlet and spa tub air inlet
AS BEFORE
connections.
• Air connection nut is not securely
tight.
• Air bubble channel passage inside
the tub broken or leaking.
• Air blower failure.
S AVE THESE INSTRUCTIONS
CAUSE
" position.
(353IO) SPA ENGLISH 7.5" X 10.3" PANTONE 295U 11/19/2021
SOLUTION
• Ensure air valve cap is securely closed.
• Fill up the spa tub with air then make sure the
air valve base is tighten, see "Spa Tub Air Valve
Fastening" section.
• Put liquid soap and water in a squirt bottle and
spray on seams. If there is a leak it will bubble.
After you fi nd the leak, clean and dry the leaking
area, then apply the repair patch that comes with
your spa.
• Always turn the air passage selection dial to
"
" position after fi nish infl ation fi rst, before
switching off the air bubble pump, so no air
escapes.
• Tighten inlet and outlet connections.
• Coat the o-ring with petroleum jelly for water
proof.
• Remove grid from inside spa with a screwdriver,
ensure inlet/outlet O-ring is in place, clean and
not damaged.
• Ensure control panel, back cover and all inlet/
outlet are securely connected.
• Ensure ground is level, fi rm and smooth.
• Replace the failed fi lter motor with a new one.
• Increase the sanitation system operating time
and ensure the heater is off during the sanitation
process. See "Sanitation System Operating
Instructions".
• Use a SPA cover when the SPA is not in use and/
or when the sanitation system is operating.
• Increase the sanitation system operating time and
test the water using the test strips. See "Sanitation
System Operating Instructions".
• Check and clean the cell if necessary. See
"Maintenance".
• Ensure the o-ring is in place.
• Tighten/reinstall hose adaptor.
• Finger tighten during infl ation.
• If problem persists, contact Intex Service Center.
• Ensure the o-ring is in place.
• Finger tighten all nuts.
• Use repair patch to repair any puncture.
• If problem persists, contact Intex Service Center.
353
English
A
Page 31

Publicité

loading

Ce manuel est également adapté pour:

Purespa greystone deluxe sb-hswf20