The new batteries have to be connected to the battery supply lines, and
arrange these such that they are not crushed between the housing parts.
Then place the batteries into the battery compartment provided for this
purpose.
-
Place the battery compartment cover onto the bottom part and tighten the
screw.
See figure 7:
Make your contribution to environmental protection! Do not
dispose of discharged batteries in the household garbage.
Instead, take them to a collecting point for discharged batteries
and special waste material. Please inform yourself in your
community.
9.5 Calibration
To maintain the specified precision of the measurement results, the instrument
must be recalibrated at regular intervals by our factory service. We recommend
a recalibration interval of one year. Send the appliance to the following
address:
Benning Elektrotechnik & Elektronik GmbH & CO. KG
Service Centre
Robert-Bosch-Str. 20
D - 46397 Bocholt
10. Technical data of the measuring accessories
-
Standard: EN 61010-031,
-
Maximum rated voltage to earth () and measuring category:
With push-on caps: 1000 V CAT III, 600 V CAT IV,
Without push-on caps: 1000 V CAT II,
-
Maximum rated current: 10 A,
-
Protective class II ( ), continuous double or reinforced insulation,
-
Contamination class: 2,
-
Length: 1.4 m, AWG 18,
-
Environmental conditions:
Maximum barometric elevation for making measurements: 2000 m,
Temperatures: 0 °C to + 50 °C, humidity 50 % to 80 %
-
Only use the test leads if in perfect and clean condition as well as according
to this manual, since the protection provided could otherwise be impaired.
-
Throw the test leads out if the insulation is damaged or if there is a break in
the cable/ plug.
-
Do not touch the bare contact tips of the test leads. Only grab the area
appropriate for hands!
-
Insert the angled terminals in the testing or measuring device.
11. Environmental notice
At the end of the product's useful life, please dispose of it at appropri-
ate collection points provided in your country.