recorded. On consultation, the names of the repair order and the user are displayed.
• The page number is indicated at the top left..
• All repair orders are stored in the file called catalog.GYS.
• This file contains the total number of repair orders, the name of each repair order and the name of each user. There is a maximum of 100 repair
orders.
User programs
Saving the settings allows you to define a user program in order to easily find its settings for future use. 20 memory slots are available. Each of them
contains the following settings: tool, arm, welding power, welding time and pressure.
A program can be associated to the clamp or gun.
The button
is used to save the current settings of the manual mode (power, time and pressure). The 20 memory slots are then indicated by their
identifier (for those used) or by a symbol» ---» for free slots..
The ID is entered using the 4 keys
stored.
The
button is used to access the settings previously saved. Choosing an empty location has no effect.
Briefly pressing key
The key
exits the program selection mode, switches the machine to manual mode with the parameters and tool saved in the program.
To deactivate a program, simply change the value of a parameter in one of the three modes manual, normal or multiplate or change the tool (clamp,
gun) using the
button.
The
key allows you to view a previously saved report and read it back on the screen.
SD memory card (ref. 050914)
This card allows the user to link the machine to a PC in order to:
• Retrieve logs (reports), keep a record of the work done, and eventually send it to an insurance company.
• Update welding parameters, add new languages.
• The GYSPOT software for editing parameters on a PC is stored on the SD memory card.
• The instructions are is stored on the SD memory card.
ASSEMBLY AND REPLACEMENT OF THE ARMS ON THE G CLAMP
The warranty does not cover anomalies and damages due to improper assembly of the G-clamp arms.
IMPORTANT :
- do not use copper grease on the arms.
- keep the arm base and arm support on the clamp clean to ensure a good flow of current between the parts in contact.
- If not used for a long time, always store the machine with an arm mounted on the clamp to avoid dust on the arm support.
Procedure for changing the arms :
During the replacement of the arms on the clamp, the cooling circuit pump must be switched off. To do this, place yourself in the «Clamp Setting»
mode on the machine; the red light on the clamp button (FIG 2 -12) indicates that the pump is off. The electrode retracts into the clamp to allow the
arm to be removed.
1
The latch sticks out on the lock side
2
The lever must be in the rear position stop (~120°)
3
The arrows must be aligned
4
Tilt the arm about 15° and remove it from its housing (the pins must slide into the groove)
3
52
BMW C7502654 - GYSPOT PTI GENIUS
. When entering an ID that has already been used, the machine will delete the settings that were previously
deletes the selected program from the list of saved programs.
The memory space is sufficient to ensure an autonomy of more than 65,000 points.
The machine can operate without a memory card in «manual» mode only.
If the memory card is not inserted in the card reader, the following message appears. The machine must be
stopped and restarted after inserting the SD card.
Important : It is necessary to turn off the power to the machine before removing the SD card from its rea-
der and restart the machine only after inserting the SD card into its reader, otherwise the data saved on the
SD card may be lost.
2
4
1
2
4
3
1
EN