EN
D
OPERATION
SET UP THE LASER
Before setting up the laser select the appropriate legs for the tube diametre and mount them on the
bottom of the laser (diametre DN 100: laser without legs!). If the vial shown in the display is centered
and the direction arrow is in the middle (see page 19) the instrument is set up correctly. Now adjust
the inclination and align the laser dot to the target. Continue aligning each pipe end to the target.
REMOTE CONTROL
The FKL 44 pipe laser is supplied with an RF remote control.
With the remote control all features can be controlled.
Exception: ON/OFF button:
The ON/OFF function can only be operated on the instrument!
Remote control range front: 100 m (laser emitting window)
Remote control range back: 50 m (end of the handle).
POWER ON/OFF THE LASER / REMOTE CONTROL
Power on the laser and the remote control with the ON/OFF button each; wait for the completion of the
self-levelling procedure. The grade value set last will be displayed. Press the button again to power off
the laser / remote control.
CHANNEL SELECTION
Select the required channel with this button (channel 1 to 9); the remote control channel must be set to
the same channel as the laser.
INDICATION OF THE LASER START POINT
Press the button to activate the LED of the laser start point.
From this point on the grade of the laser dot will start
(which influences the grade setting).
Press the button again to quit.
18
Start laser point
H
L1
L2
Grade = H / L1 + L2