Battipav srl
THE MACHINE IS TO BE CONNECTED TO THE POWER SUPPLY BY A RESIDUAL CURRENT CIRCUIT BREAKER
(RCCB) WITH THE FOLLOWING CHARACTERISTICS:
RCCB
In 16 A Id 30 mA
N.B. To ensure correct functioning, periodically check the efficiency of RCCBs by pressing the push-button on the front of the device.
•
Make sure that the section of the power supply cable cores has been measured according to the starting
current and its length. For cables up to 50 m long, a section of 4 mm
•
Before connecting the machine to the power socket, check that the power supply voltage corresponds to that
shown on the plate on the machine.
•
The machine must be connected to an effective earth wire.
In case of doubt, do not connect the machine.
For codes xxx / M 230V 1F, connect the machine to a protected line with a magnetothermic switch in curve D,
specific for user devices with high inrush current.
IN THE EVENT OF REVERSE MOTOR ROTATION, INVERT THE TWO PHASE PINS INSIDE THE POWER PLUG, AS
INDICATED BELOW: only for codes art.9XXXX / T380 and art.9XXXX / T380S1
18
• with a screwdriver with a slotted impression, press in the appropriate seat and turn the two phase pins;
• check the correct direction of rotation.
BLADE ASSEMBLY / DISASSEMBLY
Before performing any operation or adjustment, disconnect the machine from the supply mains.
Unscrew the knobs and the locking nut located on the disc cover and remove it.
16
Remove the blade fixing nut using the 30 mm spanner and the 6 mm Allen wrench.
THE BLADE FIXING NUT HAS A LEFT-HAND THREAD.
•
Install the new blade, checking for correct direction of rotation as clearly indicated on the tool.
•
Tighten the blade and put the blade cover guard back in position.
IN ADDITION TO THE KNOBS ALWAYS REASSEMBLE THE LOCKING NUT ON THE DISC COVER.
FOR THE BLADE DISASSEMBLY OPERATIONS, PROCEED AS INDICATED BELOW.
Wearing gloves to protect your hands, hold the diamond blade firmly and use the other hand to unscrew the
17
fixing nut with a 30 mm spanner.
CONTROL DEVICES
19 20
The EXPERT machine is equipped with a control board made up of:
1) START BUTTON: (GREEN COLOUR for EXPERT 400, BLACK COLOUR for EXPERT 500/600 and 700)
Press the button fully to activate machine starting.
2) REGULAR STOP BUTTON: (RED COLOUR)
3) DEVICE FOR DISCONNECTION FROM THE MAINS (Plug)
Machine power supply point. During the maintenance phases, take out the plug from the device in order to
disconnect the machine from the mains.
4) MAINS PRESENCE WARNING LIGHT (WHITE)
On: presence of mains voltage. Off: lack of mains voltage.
5) MACHINE OPERATION WARNING LIGHT (GREEN)
It indicates that the machine is working.
6) OVERCURRENT CIRCUIT BREAKER
It intervenes when there is overcurrent, interrupting the machine supply. Its intervention is indicated by the
expulsion of the manual reset. In case of intervention of the circuit breaker, wait a few minutes and reset it by
(EXPERT 400):
(EXPERT 400)
(EXPERT 400):
(EXPERT 400):
is enough.