Télécharger Imprimer la page

Baseline Unit; Accessories; Connecting Flanges; Transport - Dimplex SI 50TE Instructions D'installation Et D'utilisation

Publicité

Les langues disponibles

Les langues disponibles

3
3

Baseline Unit

The basic device consists of a ready-to-use heat pump for indoor
installation, complete with sheet metal casing, control panel and
integrated controller. The refrigerant circuit contains the Kyoto
protocol approved refrigerant R404A with a GWP value of 3260.
It is CFC-free, does not deplete ozone and is non-flammable.
All components required for the operation of the heat pump are
located in the control box. A sensor for the external wall temper-
ature including mounting hardware as well as a strainer are sup-
plied with the heat pump. The voltage supply for the load and
control current must be provided by the customer.
The control wire of the brine pump (to be provided by the cus-
tomer) is to be connected to the control box. When so doing, a
motor protecting device is to be installed, if required.
The collector including the brine manifold must be provided by
the customer.
1)
Control
2)
Evaporator
3)
Condenser
4)
Compressor
5)
Transport securing devices
6)
Filter drier
E-3
4

Accessories

4.1 Connecting Flanges

The use of flat-sealing connecting flanges allows the unit, as an
option, to be connected by means of flanges.
5

Transport

For the transport by means of a hand truck or boiler trolley, po-
sition the latter under the front end of the unit below the transport
security device.
For transport on a level surface, the unit can be lifted from the
rear or from the front by means of a lift truck or forklift. In this
case, the transport securing device is not imperative.
ATTENTION!
The heat pump must not be tilted more than max. 45° (in either direction).
After the transport, the transport securing device is to be re-
moved on either side at the bottom of the unit.
ATTENTION!
The transport securing device is to be removed prior to commissioning.
To remove the panelling, open the individual covers by unscrew-
ing the respective turn-lock fasteners and then gently tilting the
covers away from the device. Then lift them up out of the mount-
ings.

Publicité

loading

Ce manuel est également adapté pour:

Si 75teSi 100teSi 130te