CONNECTING TO GAS SUPPLY
CHECK THESE SPECIFICATIONS BEFORE CONNECTING THE APPLIANCE TO
THE GAS CYLINDER /BOTTLE. THE PRESSURE REGULATORS CONNECTED
BETWEEN THE GAS CYLINDER AND APPLIANCE MUST CONFORM WITH THE
CATEGORIES GIVEN IN THE TABLE BELOW.
This appliance is designed for running off the following types of gas at the corresponding operating pressures. The gas
category (or categories) of the appliance is given on the specifications label affixed to the appliance.
CATEGORY AND COUNTRY OF DESTINATION
I3B/P(30)
AT BE DE DK FI GB NL NO PT SE SI
I3+ (28-30/37)
BE CH ES FR GB IE IT PT SI
MODEL
HBH2000L - HBH2000R
WHEN INSTALLING AND CONNECTING THE APPLIANCE TO THE GAS SUPPLY,
ENSURE THAT THE GAS SUPPLY HOSE IS NOT TWISTED, STRETCHED OR
SUBJECTED TO ANY FORM OF STRAIN WHICH COULD CREATE A HAZARD.
The gas supply pipe connected to the appliance must be a rigid metal pipe with sealed fittings. It is possible to fit a
flexible hose, however, in this case the following conditions must be respected:
a) The hose can be accessed easily for inspection;
b) The hose must be protected against coming into contact with parts which heat up (for example parts
underneath the burners);
c) The hose must be protected against being damaged (twisting, pulling, trapping,....);
d) The hose must be protected against being trapped by moving parts (e.g. drawers);
e) The hose must not have a length over 1.5 m;
f) The hose must be replaced before its expiry date;
Once the appliance has been connected to the gas supply check for gas leaks utilising a non-corrosive fluid.
Do not use a water and soap solution. NEVER USE A FLAME TO TEST FOR GAS LEAKS.
GAS PRESSURE
30 mbar Butane (G30)
30 mbar Propane (G31)
28-30 mbar Butano (G30)
37 mbar Propano (G31)
TOTAL NOMINAL THERMAL
CAPACITY
kW - gr/h
4,4 - 335
AIR VOLUME REQUIRED FOR
COMBUSTION
m
/h
3
8,8

Publicité