13.5 Pre-Tare setting - FnC 09
Under this menu item, Pre-Tare setting can be carried out. Two settings are possible:
00
Pre-Tare not possible when a load is on the weighing plate
01
Pre-Tare possible when a load is on the weighing plate
Procedure with setting „00":
Ensure that there is no load on the weighing plate
Press
, „Pre-Tare" will be displayed flashing
Use the numeric keyboard to enter the Pre-Tare value, e.g. 1000 g
Confirm by
Delete Pre-Tare value by
48
, the Pre-Tare value will be displayed as a negative value.