Central ventilation units AIR1 RH
the unit is operated. These conditions can influence the measurement result on site and differ from the catalogue data.
Unit types
1500
Air flow (m
3
/h)
1400
328
Minimum volume flow
(m
3
/h)
Rated current Fan (A)
2,17 /
2,17 /
0
Rated current
6,06 /
Aux.-heat. (A) (opti-
6,06 /
6,06
onal)
Rated current max.
8,3 /
8,3 /
total with electrical
auxiliary heater (A)
7,4
Power consumption
1
Fan (kW)
Power cons. Aux.-heat.
4,2
(kW) (optional)
Mains voltage /
3~
Frequency
400 V
50 Hz
Filter class (extract
ePM10
50 %
air/outside air)
ePM1
55 %
Weight (kg)
315
Protection class with
IP54
weather prot. cover
Protection class w/o
IP31
weather prot. cover
Unit types
1500
Air flow (m
3
/h)
1400
Minimum volume flow
328
(m
3
/h)
Rated current Fan (A)
2,17 /
2,17 /
0
Rated current
6,06 /
Aux.-heat. (A) (opti-
6,06 /
onal)
6,06
Rated current max.
8,3 /
8,3 /
total with electrical
auxiliary heater (A)
7,4
1
Power consumption
Fan (kW)
Power cons. Aux.-heat.
4,2
(kW) (optional)
Mains voltage /
3~
400 V
Frequency
50 Hz
ePM10
Filter class (extract
air/outside air)
50 %
ePM1
55 %
Weight (kg)
320
Protection class with
IP54
weather prot. cover
Protection class w/o
IP31
weather prot. cover
AIR1 RH
2000
3000
5000
6000
2200
2900
4400
5500
328
788
662
843
3,39 /
4,56 /
7,6 /
7,29 /
3,39 /
4,56 /
7,6 /
7,29 /
0
4,56
7,6
7,29
8,37 /
13,13 /
8,37 /
13,13 /
8,37
13,13
11,8 /
17,7 /
11,8 /
17,7 /
9,7
19
1,56
3
5
4,8
5,8
9,1
3~
3~
3~
3~
400 V
400 V
400 V
400 V
50 Hz
50 Hz
50 Hz
50 Hz
ePM10
ePM10
ePM10
ePM10
50 %
50 %
50 %
50 %
ePM1
ePM1
ePM1
ePM1
55 %
55 %
55 %
55 %
361
438
629
775
IP54
IP54
IP54
IP54
IP31
IP31
IP31
IP31
AIR1 RH/SO
2000
3000
5000
6000
2200
2900
4400
5500
328
788
662
843
3,39 /
4,56 /
7,6 /
7,29 /
3,39 /
4,56 /
7,6 /
7,29 /
0
4,56
7,6
7,29
8,37 /
13,13 /
8,37 /
13,13 /
8,37
13,13
11,8 /
17,7 /
11,8 /
17,7 /
9,7
19
1,56
3
5
4,8
5,8
9,1
3~
3~
3~
3~
400 V
400 V
400 V
400 V
50 Hz
50 Hz
50 Hz
50 Hz
ePM10
ePM10
ePM10
ePM10
50 %
50 %
50 %
50 %
ePM1
ePM1
ePM1
ePM1
55 %
55 %
55 %
55 %
368
450
645
787
IP54
IP54
IP54
IP54
IP31
IP31
IP31
IP31
49
8000
9500
12000
15000
8000
9500
12500
15000
1079
1380
1686
1686
10,94 /
10,64 /
15,19 /
18,23 /
10,94 /
10,64 /
15,19 /
18,23 /
10,94
10,64
15,19
18,23
7,2
7
10
12
3~
3~
3~
3~
400 V
400 V
400 V
400 V
50 Hz
50 Hz
50 Hz
50 Hz
ePM10
ePM10
ePM10
ePM10
50 %
50 %
50 %
50 %
ePM1
ePM1
ePM1
ePM1
55 %
55 %
55 %
55 %
888
1085
1160
1500
IP54
IP54
IP54
IP54
IP31
IP31
IP31
IP31
8000
9500
12000
15000
8000
9500
12500
15000
1079
1380
1686
1686
10,94 /
10,64 /
15,19 /
18,23 /
10,94 /
10,64 /
15,19 /
18,23 /
10,94
10,64
15,19
18,23
7,2
7
10
12
3~
3~
3~
3~
400 V
400 V
400 V
400 V
50 Hz
50 Hz
50 Hz
50 Hz
ePM10
ePM10
ePM10
ePM10
50 %
50 %
50 %
50 %
ePM1
ePM1
ePM1
ePM1
55 %
55 %
55 %
55 %
905
1106
1184
1531
IP54
IP54
IP54
IP54
IP31
IP31
IP31
IP31