Illustration E
10.Fit the dirt receptacle in the device.
Illustration D
WARNING
Improper handling when locking the dirt
receptacle
Risk of crushing
Under no circumstances should you hold
your hands between the dirt receptacle and
filter ring or allow them to come close to the
lifting mechanism while locking it.
Lock the dirt receptacle by operating the le-
vers with both hands.
11.Lock the dirt receptacle with the levers.
12.Fit the pressure equalisation hose on
the dirt receptacle
Switching on the device
1. Plug the mains plug into the socket.
2. Switch on the device at the trigger.
Illustration H
The switch has multiple level settings:
0 The device is off.
1 Motor 1 is switched on.
2 Motors 1 and 2 are switched on.
3. Start vacuuming.
Reading the minimum volumetric
A gauge is mounted on the front of the de-
vice that shows the vacuum intensity (see
chapter Device description).
The table shows the maximum vacuum in-
tensity value. This value depends on the
unit performance and the suction hose
used.
ATTENTION
Suction loss
If the specified value is exceeded, the air
speed in the suction hose drops below 20
m/s.
Clean the filter when the value is reached,
or sooner (see chapter Cleaning the filter.
Replace the filter if the value is not signifi-
cantly reduced by cleaning (see chapter
Replacing the filter).
Hose diameter
DN40
DN50
22
flow
Value
180 mbar (18 kPA)
160 mbar (16 kPA)
 Clean the filter before or when the spec-
ified value is reached.
Cleaning the filter
Note
Clean the filter regularly to avoid declining
suction power.
Illustration I
1. Move the filter cleaning handle back and
forth several times to clean the filter.
Switching off the device
1. Switch off the device at the On/Off
switch.
2. Empty and clean the dirt receptacle.
3. Remove the accessory and clean and
dry if necessary.
Each time after use
Emptying the dirt receptacle
The dirt receptacle must be emptied as
necessary and after each use.
1. Switch off the device and disconnect
from the mains supply.
2. Clean the filter.
3. Remove the dirt receptacle from the de-
vice and replace the dust bag (see chap-
ter Replacing the dust bag).
Note
Only move the dirt receptacle on its rollers.
Do not use a crane, forklift or similar
means.
Removing the suction head
1. Switch off the device and disconnect it
from the mains supply.
2. Open the suction head lock.
Illustration J
3. Remove the suction head and put it to
one side.
Storing the device
1. Wind the mains cable onto the cable
holders.
2. Store the device in a dry room and se-
cure it against unauthorised use.
CAUTION
Failure to observe the weight
Risk of injury and damage
English