DIMENSIONS
MODELS
cm
PC-94ET
40x90x90h
PCT-94ET
40x90x29h
40x90x90h
PCQ-94ET
PCQT-94ET
40x90x29h
PCC-94ET
40x90x90h
40x90x29h
PCCT-94ET
PC-98ET
80x90x90h
80x90x29h
PCT-98ET
PCQ-98ET
80x90x90h
PCQT-98ET
80x90x29h
80x90x90h
PCC-98ET
PCCT-98ET
80x90x29h
120x90x90h
PC-912ET
120x90x29h
PCT-912ET
PCQ-912ET
120x90x90h
120x90x29h
PCQT-912ET
160x90x90h
PC-916ET
120x90x90h
PCQ-916ET
DIMENSIONS
MODELS
cm
80x90x90h
CF4-98ET
CFQ4-98ET
80x90x90h
CFC4-98ET
80x90x90h
CF6-912ETV
120x90x90h
CFQ6-912ETV
120x90x90h
CF6-912ET
120x90x90h
120x90x90h
CFQ6-912ET
160x90x90h
CF8-916ETV
120x90x90h
CFQ8-916ETV
160x90x90h
CF8-916ET
CFQ8-916ET
120x90x90h
The data plate is on the front (see diagram in electric connection item) and has all the data necessary for the connection.
When fitting, the appliance must be levelled using a spirit level; slight differences of level can be adjusted by screwing
or unscrewing the adjustable feet. The main switch or the socket must be near the appliance and easily accessible.
It is advisable to place the appliance under an extractor hood so that steam is extracted rapidly. If the appliance is placed
near walls, dividing panels, kitchen furniture, decorative finishing, etc. , these should be in flameproof material;
otherwise it is necessary to cover them with non-flammable material.
Above all, it is necessary to ensure that the fire prevention norms are observed.
GB
IT
COOKING TOP TECHNICAL DATA TABLE
POWER SUPPLY
400V/2N 50/60 Hz
400V/2N 50/60 Hz
400V/2N 50/60 Hz
400V/2N 50/60 Hz
400V/2N 50/60 Hz
400V/2N 50/60 Hz
400V/3N 50/60 Hz
400V/3N 50/60 Hz
400V/3N 50/60 Hz
400V/3N 50/60 Hz
400V/3N 50/60 Hz
400V/3N 50/60 Hz
400V/3N 50/60 Hz
400V/3N 50/60 Hz
400V/3N 50/60 Hz
400V/3N 50/60 Hz
400V/3N 50/60 Hz
400V/3N 50/60 Hz
RANGE TECHNICAL DATA TABLE
POWER SUPPLY
400V/3N 50/60 Hz
400V/3N 50/60 Hz
400V/3N 50/60 Hz
400V/3N 50/60 Hz
400V/3N 50/60 Hz
400V/3N 50/60 Hz
400V/3N 50/60 Hz
400V/3N 50/60 Hz
400V/3N 50/60 Hz
400V/3N 50/60 Hz
400V/3N 50/60 Hz
INSTRUCTIONS FOR INSTALLATION
INSTALLATION
IE
CH
MAXIMUM
MAXIMUM
ABSORPTION A
POWER kW
15,22
15,22
17,39
17,39
14,78
14,78
30,43
30,43
34,78
34,78
29,57
29,57
30,43
30,43
34,78
34,78
45,65
(15,22+30,43)
(7+21)
52,17
(34,78+17,39)
(24+8)
MAXIMUM
MAXIMUM
ABSORPTION A
POWER kW
37,83
42,17
(34,78+14,8)
(16 + 6,7)
36,96
45,2
(14,8+30,4)
(6,7+21)
49,6
(14,8+34,8)
(6,7+24)
45,2
(14,8+30,4)
(9,2+21)
49,6
(14,8+34,8)
(9,2+24)
60,4
(30+30,4)
(16,2+21)
67
(32,2+34,8)
(17,2+24)
60,4
(30+30,4)
(20,4+21)
67
(32,2+34,8)
(21,4+24)
26
POWER SUPPLY
CABLE (Silicone)
7
4x1,5 mm²
7
4x1,5 mm²
8
4x2,5 mm²
8
4x2,5 mm²
6,8
4x1,5 mm²
6,8
4x1,5 mm²
14
5x4 mm²
14
5x4 mm²
16
5x6 mm²
16
5x6 mm²
13,6
5x4 mm²
13,6
5x4 mm²
21
5x4 mm²
21
5x4 mm²
24
5x6 mm²
24
5x6 mm²
28
4x1,5 mm² +
5x4 mm²
32
5x6 mm² +
4x2,5 mm²
POWER SUPPLY
CABLE (Silicone)
20,7
5x6 mm²
22,7
5x6 mm² +5x6
mm²
20,3
5x6 mm²
27,7
5x4 mm² +5x4
mm²
30,7
5x6 mm² +5x6
mm²
30,2
5x4 mm² +5x4
mm²
33,2
5x6 mm² +5x6
mm²
37,2
5x4 mm² +5x4
mm²
41,2
5x6 mm² +5x6
mm²
41,4
5x4 mm² +5x4
mm²
45,4
5x6 mm² +5x6
mm²