Error codes
These error codes are for guidance only and all faults should be diagnosed and
repaired by a qualified technician.
Display
E1
E2
E7
C1
E3
E4
C2
EL / EH
EU
IGBT: Insulated Gate Bipolar Transistor
84
IH2350M_OP 25oct 1.indd 84
IH2350M_OP 25oct 1.indd 84
Possible Cause
Glass plate temperature sensor
failure – open circuit.
Glass plate temperature sensor
failure – short circuit.
Glass plate temperature sensor
failure
High temperature of glass plate
sensor
Temperature sensor of the IGBT
failure – open circuit
Temperature sensor of the IGBT
failure – short circuit
High temperature of IGBT
Abnormal supply voltage
Communication error.
Possible Solution
Check the connection or replace the
glass plate temperature sensor.
Contact the after-sales service
Wait for the temperature of glass plate
return to normal.
Touch
to restart the hob.
Replace the power board.
Contact the after-sales service.
Wait for the temperature of glass plate
return to normal.
Touch
to restart the hob.
Inspect whether power supply is
normal and then turn the hob on.
Reinsert the connection between the
display board and the power board.
Replace the power board or the display
board.