Télécharger Imprimer la page

Napoleon Ascent 36 Serie Manuel D'installation Et D'utilisation page 19

Publicité

Les langues disponibles

Les langues disponibles

2.8
rear exit horizontal termination
Simple venting configuration
(only two 90° elbows)
For vent configurations requiring more than two 90° elbows, the following formulas apply:
Formula 1: H
< V
T
T
Formula 2: H
+ V
< 40 feet (12.2m)
T
T
Example:
V
= 9 FT (2.7m)
1
V
= 6 FT (1.8m)
2
V
= V
+ V
= 9FT (2.7m) + 6FT (1.8m) = 15FT (4.6m)
T
1
2
H
= 3 FT (0.9m)
1
H
= 2 FT (0.6m)
2
H
= 1.5 FT (0.5m)
3
H
= H
+ H
+ H
= 3FT (0.9m) + 2FT (0.6m) + 1.5FT (0.5m) = 6.5FT (2m)
R
1
2
3
H
= .03 (four 90° elbows - 90°) = .03 (360° - 90°) = 8.1 FT (2.5m)
O
H
= H
+ H
= 6.5FT (2m) + 8.1FT (2.5m) = 14.6FT (4.5m)
T
R
O
H
+ V
= 14.6FT (4.5m) + 15FT (4.6m) = 29.6 FT (9m)
T
T
Formula 1:
H
< V
T
T
14.6 FT (4.5m) < 15 FT (4.6m)
Formula 2:
H
+ V
T
T
29.6 FT (9m) < 40 FT (12.2m)
Since both formulas are met, this vent configuration is acceptable.
(H
< 40 FT (12.2m)
venting requirements
) < (V
)
T
T
See graph to determine the required vertical rise V
horizontal run H
40 (12.2)
35.3 (10.7)
REQUIRED
30 (9.1)
VERTICAL
RISE IN
20 (6.1)
FEET
(METERS) V
T
10 (3.1)
2 (0.6)
0
2.5
(0.8)
1.6
(0.5)
HORIZONTAL VENT RUN PLUS OFFSET IN FEET (METERS) H
The shaded area within the lines represents acceptable values for H
for the required
T
.
T
5
7.5
10
12.5
15
(1.5)
(2.3)
(3.1)
(3.8)
(4.6)
and H
T
90°
H
3
V
2
90°
H
2
90°
V
1
H
1
90°
W415-1847 / A / 03.11.19
EN
17.5
20
(5.3)
(6.1)
T
T
19

Publicité

loading

Ce manuel est également adapté pour:

B36ntrB36ntreB36ptrB36ptre