Télécharger Imprimer la page

Napoleon Ascent 36 Serie Manuel D'installation Et D'utilisation page 21

Publicité

Les langues disponibles

Les langues disponibles

2.9
top and rear exit vertical termination
Simple venting configurations.
For vent configurations requiring one or more 90° elbows (top exit) or one or more 90° elbows
(rear exit), the following formulas apply:
Formula 1: H
< V
T
T
Formula 2: H
+ V
< 40 feet (12.2m)
T
T
Example:
V
= 5 FT (1.5m)
1
V
= 6 FT (1.8m)
2
V
= 10 FT (3.1m)
3
V
= V
+ V
+ V
= 5FT (1.5m) + 6FT (1.8m) + 10FT (3.1m) = 21 FT (6.4m)
T
1
2
3
H
= 8 FT (2.4m)
1
H
= 2.5 FT (0.8m)
2
H
= H
+ H
= 8FT (2.4m) + 2.5FT (0.8m) = 10.5FT (3.2m)
R
1
2
H
= .03 (four 90° elbows - 90°)
O
= .03 (360° - 90°) = 8.1 FT (2.5m)
H
= H
+ H
= 10.5FT (3.2m) + 8.1FT (2.5m) = 18.6FT (5.7m)
T
R
O
H
+ V
= 18.6FT (5.7m) + 21FT (6.4m) = 39.6FT (12.1m)
T
T
Formula 1:
H
< 3.5V
T
18.6 FT (5.7m) < 21 FT (6.4m)
Formula 2:
H
+ V
T
39.6FT (12.1m) < 40 FT (12.2m)
Since both formulas are met, this vent configuration is acceptable.
(H
REQUIRED
VERTICAL RISE
IN FEET
(METERS)V
T
< 40 FT (12.2m)
T
venting requirements
) < (V
)
T
T
See graph to determine the required vertical rise V
required horizontal run H
40 (12.2)
30 (9.1)
20 (6.1)
T
10 (3.1)
3 (0.9)
0
(1.5)
HORIZONTAL VENT RUN PLUS OFFSET IN FEET
The shaded area within the lines represents acceptable
values for H
T
.
T
5
10
15
20
(3.1)
(4.6)
(6.1)
(METERS) H
T
and H
T
T
W415-1847 / A / 03.11.19
EN
for the
21

Publicité

loading

Ce manuel est également adapté pour:

B36ntrB36ntreB36ptrB36ptre