A terminal shall not terminate directly above a sidewalk or paved driveway which is located between two single family dwellings
and serves both dwellings. Local codes or regulations may require different clearances.
Do not allow the inside liner to bunch up on horizontal or vertical runs and elbows. Keep it pulled tight. A 1¼" (31.8mm) air gap
all around between the inner liner and outer liner is required for safe operation.
This appliance is certifi ed for use with a power vent kit. Contact your local authorized dealer for more information.
For optimum performance, it is recommended that all horizontal runs have a minimum 1/4" rise per foot or 21mm
rise per meter using fl exible venting.
2.1
typical vent installation
8" (203mm)
minimum
REQUIRED RISE ON HORIZONTAL VENTING
Rear Vent
Rigid Venting
Flexible Venting
Top Vent
Rigid Venting
Flexible Venting
Rear Vent
Rigid Venting
Corner
Flexible Venting
24" (61cm)
maximum
TOP VENT
venting requirements
0" / FT
0" / FT
0" / FT
0" / FT
0"
6" (152mm)
16" (40.6cm)
minimum
40ft (12m)
maximum
3ft (1m)
minimum
34 5/8"
(86cm)