Télécharger Imprimer la page

BWT BIOSTIL MAX UV Serie Notice Originale page 25

Publicité

Les langues disponibles

Les langues disponibles

Model
US Public Health 16 mJ/cm2 @ 95% UVT
Standard 30 mJ/cm2 @ 95% UVT
NSF/EPA 40mJ/cm2 @ 95% UVT
Chamber
Controller 100-250 VAC
Inlet/Outlet Port Size
Shipping Weight
Voltage
Max. Current
Power Consumption
Lamp Watts
Total Running Time
Maximum Operating Pressure
Minimum Operating Pressure
Ambient Water Temperature
Lamp Type
Visual "Power-On"
Audible Lamp Failure
Lamp Replacement Reminder
Visual Lamp Life Remaining
Total Running Time
Chamber Material
LAMP LIFE REMAINING (DAYS)
The controller tracks the number of days of operation of the lamp and the controller. The default
screen will display the total lamp life remaining (in days). The controller will count down the number
of days remaining until the lamp requires changing (365 days to 1 day). At "0" days, the controller
will display and sound an intermittent audible chirp (1 second on, 5 seconds off), indicating the need
to change the lamp.
UNDERSTANDING YOUR "A3" CODE
DEFERRAL
- Once the "A3" or end of lamp life message is shown on the LED display, the audible
alarm can be deferred up to 4 separate times. The delay is designed to allow you time to address the
alarm while you obtain a new UV lamp.This can be done by simply depressing the timer reset button
for 5 seconds, which is located on the left side of the controller. Each time the timer reset button is
pressed the controller alarm is deferred seven days. Once the final 7 day deferral has been reached
the alarm can only be silenced by changing the UV lamp and manually resetting the controller timer.
RESETTING LAMP LIFE
NOTE:
Even though the alarm on the system can be deferred for a period of time, it is
important to address each and every alarm condition as they are indicating that there is a
potential problem with the system and should be remedied.
SPECIFICATIONS
UV1000
12 gpm (45 lpm) (2,7 m3/h)
5 gpm (19 lpm) (1,1 m3/h)
3,5 gpm (13 lpm) (0,8 m3/h)
33cm x 8,9cm (13" x 3.5")
3,6 kg (8 lbs)
32 W
22 W
BASIC SYSTEMS ON CONTROLLER
Technical manuel BWT BIOSTIL MAX UV - code P0011133 - Rev 2 - 04/11/2020
UV1800
16 gpm (60 lpm) (3,6 m3/h)
9 gpm (34 lpm) (2,0 m3/h)
7 gpm (26 lpm) (1,6 m3/h)
45cm x 8,9cm (15" x 3.5")
17,2 cm x 8,1 cm x 6,4 cm
(6.8" x 3.2" x 2.5")
Combo 3/4" FNPT/1'' MNPT
5,4 kg (12 lbs)
120-240 V / 50/60 Hz
1,5 Amp
35 W
25 W
Yes
125 psi (861 kPa)
15 psi (103 kPa)
2-40 ºC (36-104 ºF)
Sterilume™-HO (high-output)
Yes
Yes
Yes
Yes
Yes
304SS
UV2700
34 gpm (130 lpm) (7,8 m3/h)
18 gpm (70 lpm) (4,2 m3/h)
14 gpm (54 lpm) (3,3 m3/h)
59,6cm x 8,9cm (23.5" x 3.5")
7,7 kg (17 lbs)
60 W
46 W
25