REPLACING UV LAMP
NOTICE
- Reset lamp life timer after lamp replacement.
- Do not use water during replacement of UV lamp.
Lamp replacement is a quick and simple procedure requiring no special tools.
The UV lamp must be replaced after 9000 hours of continuous operation (approximately one year)
in order to ensure adequate disinfection.
PROCEDURE:
-Shut off the water line
to chamber and release
system pressure before
servicing.
-Insert the new lamp fully into
the chamber leaving about
two inches of the lamp protru-
ding from the chamber.
CLEANING AND REPLACING QUARTZ SLEEVE
NOTE:
Minerals in the water slowly form a coating on the lamp sleeve. This coating must
be removed because it reduces the amount of UV light reaching the water, thereby reducing
disinfection performance. If the sleeve can not be cleaned, it must be replaced.
PREREQUISITES:
- Shut off water supply and drain all lines.
- Remove the UV lamp.
- Disconnect main power
source and allow the unit
to cool for 10 minutes.
- Attach the connector to
the lamp and note that the
connector will only allow
correct installation in one
position.
Technical manuel BWT BIOSTIL MAX UV - code P0011133 - Rev 2 - 04/11/2020
- Remove the lamp
connector by squeezing
the plastic locking tabs on
the side of the connector.
- Push the lamp connector
against lamp connector
base together until an
audible click is heard.
- Re-pressurize the system
to check for leaks.
- Remove the lamp in
upward direction from the
chamber and lamp connec-
tor base.
- Always hold the lamp at the
ceramic ends.
- Hold down the timer reset
button and reapply power to
the controller until you see
«rSEt», then release timer
reset button.
- A 5 second delay will oc-
cur until you hear an audible
tone and LED display will
read once again «365».
23