Télécharger Imprimer la page

BWT BIOSTIL MAX UV Serie Notice Originale page 19

Publicité

Les langues disponibles

Les langues disponibles

5
2
3
4
UV DISINFECTION SYSTEM
CAUTION:
Electronic controller must be connected to a Ground Fault Protected Circuit
(GFCI) receptacle and the lamp connector ground wire connected to the stainless steel cham-
ber.
The disinfection system is designed to be mounted
either horizontally or vertically at the point-of-use or
point-of-entry depending on the specific flow rate of
the unit.
If installing the chamber in horizontal position the out-
let port must be pointing upwards to ensure all air is
fully purged from the chamber.
NOTE:
The ideal installation is vertical with
the lamp connector on top. This is to prevent
water damage from occurring on the lamp
pins and lamp connector.
- The controller should be mounted either above or beside the chamber. Always mount controller
horizontally to prevent moisture from running down cordage and causing a potential fire hazard.
Drip loops in all cordage connected to controller is highly recommended.
- The complete water system, including any pressure or hot water tanks, must be sterilized before
start up by flushing with chlorine (household bleach) to destroy any residual contamination.
- The disinfection system is intended for indoor use only, do not install disinfection system where
it may be exposed to the weather.
- Install the disinfection system on cold water line only, before any branched lines.
A 5 micron sediment filter must precede the disinfection system. Ideally, the disinfection system
should be the last treatment the water receives before it reaches the faucet.
GENERAL INFORMATION
1
6
Item
Description
1
Controller 230V 50Hz
Hard glass, coated Sterilume®-HO UV lamps
2
for long, consistent life (9000 hours)
Open-ended, GE 214 fused quartz sleeve with
3
fire polished ends
4
O-ring
5
Retaining Nut
6
Mounting Brackets/Clamp Assembly
INSTALLATION
Technical manuel BWT BIOSTIL MAX UV - code P0011133 - Rev 2 - 04/11/2020
UV1000
UV1800
UV2700
P0015628
125301073
125301074
P0015626
125301075
125301077
P0015627
P0078937
125301079
-
-
-
19