Sharp PN-655RU Mode D'emploi page 43

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

If execution of the command is taking some time
W
A
I
T
When the following commands are used, "WAIT" is returned. In this case, a value will be returned if you
wait a while. Do not send any command during this period.
No ID number is attached to WAIT response.
• Commands which return WAIT:
- When repeater control is used
- When an IDSL or IDLK command is used
- When one of the following commands is used: RSET, INPS, ASNC, WIDE, EMAG, EPOS, PXSL,
POWR, AGIN, MWIN, MWIP, MWPP.
When control via RS-232C is locked (to prevent use) using the operation lock function (see
page 32)
L
O
C
K
If the current parameter is read out using "?" for the parameter (for numerical values etc.)
• Response when no ID number has been set
Example:
VOLM????
10
• Response when an ID number has been set (In the example below: ID number = 1)
Example:
VOLM????
10
001
<Communication interval>
• After OK or ERR is returned, you must send the following commands. To set a timeout for the
command response, specify 10 seconds or longer.
• Provide an interval of 100 ms or more between the command response and the transmission of the
next command.
VOLM0020
OK
INPS0001
WAIT
OK
Return code
(0D
, 0A
)
H
H
Return code
(0D
, 0A
H
E
D
Interval of 100 ms or more
Controlling the Monitor with a PC
)
H
41
E

Publicité

Chapitres

Table des Matières
loading

Table des Matières