After an interruption of work the machine should only be switched on
again if the drill bit can be turned.
Do not touch rotating parts.
Keep the handles dry, clean and free of oil and grease.
Persons under 16 years of age are not allowed to use the tool.
During use, the user and other persons standing nearby have to wear
suitable goggles, helmets, ear protectors, protective cloves and
boots.
Always work with concentration. Always work in a carefully
considered way and do not use the tool when you are not
concentrated.
During manual operation, always hold the machine with both
hands and maintain a safe standing position. Always consider
the reaction moment of the machine in case of blockage.
For further safety instructions please refer to the enclosure!
The EFB 125 P is made in protection class II. For protection purposes the
machine can only be run with a GFCI. The machine is standard equipped
with a PRCD protective switch integrated in the cord.
Attention!
!
First, check the correspondence between voltage and frequency against the
data mentioned on the identification plate. Voltage differences of
+6 % to -10 % are allowed. Use only extension cable with sufficient cross-
section (see chart). A cross-section which is too small could cause a failure
of the machine.
Recommended minimum cross-sections and maximum cable lengths
Mains Voltage
110 V
230 V
The machine is equipped with a soft start which prevents that swift automatic
circuit breakers are unintentionally triggered.
Electrical Connection
The PRCD protective switch must not lay in water.
PRCD protective switches must not be used to
switch the tool on and off.
Before starting your work, check the proper function
by pressing the TEST button.
1.5
20 m
50 m
Cross-Section mm²
19
2.5
40 m
80 m