The water shutoff should be located in the base cabinet on
■
either side of the refrigerator or some other easily accessible
area. If the water shutoff valve is not in the cabinets, the
plumbing for the water line can come through the floor. See
"Water Supply Requirements" for more information.
84" (213.4 cm)
to bottom of solid soffit
(see chart following)
C Depth
Model
Width A
(as shown above)
36
36" (91.4 cm)
42
42" (106.7 cm)
Installation Type
Standard Flush (new installation)
Retrofit Installations
B
Dimension
77"
(196 cm)
A
Width
Dimension B
(as shown above)
4" (10.2 cm)
7¹⁄
" (19.1 cm)
2
Depth C
(as shown above)
25" (63.5 cm) Min.
24" (60.9 cm) Min.
Electrical Requirements
WARNING
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
Before you move your refrigerator into its final location, it is
important to make sure you have the proper electrical connection.
If the supply cord is damaged, it must be replaced by the
manufacturer or its service agent or a similar qualified person. Do
not use a cord that shows cracks or abrasion damage along its
length or at either the plug or connection end.
Recommended Grounding Method
A 115 V, 60 Hz, AC only, 15 or 20 A fused, grounded electrical
supply is required. It is recommended that a separate circuit
serving only your refrigerator be provided. Use an outlet that
cannot be turned off by a switch. Do not use an extension cord.
IMPORTANT: If this product is connected to a GFCI (Ground
Fault Circuit Interrupter) protected outlet, nuisance tripping of the
power supply may occur, resulting in loss of cooling. Food quality
and flavor may be affected. If nuisance tripping has occurred, and
if the condition of the food appears poor, dispose of it.
NOTE: Before performing any type of installation or cleaning,
remove the top grille and turn the master power switch to OFF or
disconnect power at the circuit breaker box.
When you are finished, turn ON the master power switch or
reconnect power at the circuit breaker box. Then reset the control
to the desired setting.
9