ENGLISH
Fig. 21
A
Level the product using the 3 adjustment screws (A).
NB: If using a glass fl oor plate (cat. no. 50012994), the
product should be raised about 8-10 mm from the fl oor
using the 3 adjustment screws.
4.7 Chimney and fl ue pipe
•
The fi replace must only be connected to a chimney and
fl ue pipe approved for solid fuel fi replaces with fl ue gas
temperatures as specifi ed in «2.0 Technical Data».
•
The specifi ed distance to fl ammable materials, applies to
this stove.
•
The stove must be installed with a CE approved fl ue.
•
The distance of the fl ue pipe to combustible materials must
also be observed.
•
The cross-section of the chimney must be designed to fi t
the fi replace. Use «2.0 Technical Data» to calculate the
correct chimney cross-section.
•
The chimney must be connected in accordance with the
installation instructions of the chimney supplier.
•
Before a hole is made in the chimney, the product should
be test-mounted in order to correctly mark the position of
the fi replace and the hole in the chimney. See fi g. 1 for
minimum dimensions.
•
With a rear outlet, use a fl ue pipe bend with a sweep hatch
to allow sweeping.
•
Please note that it is extremely important for connections
to have a degree of fl exibility. This is to prevent any
movement in the installation leading to the formation of
cracks.
•
For recommended chimney draught, see «2.0 Technical
Data». For fl ue pipe dimension see "2.0 Technical Data".
NB: The chimney's diameter must be at least just as
big as the fl ue pipe.
NB! The minimum recommended chimney length is 3.5 m
from the fl ue pipe insert. If the draught is too strong, a fl ue
pipe damper can be installed and used to reduce the draught.
14
A
A
How wind and weather aff ect the stove
The performance of the stove can be aff ected considerably by
the wind acting on the chimney at diff erent strengths. It may
therefore be necessary to adjust the air supply to ensure good
combustion performance. It might also be a good idea to install
a damper in the fl ue pipe so that the chimney draught can be
regulated according to the strength of the wind.
Fog and mist can have a signifi cant impact on the chimney
draught and it might be necessary to use other combustion air
settings to ensure good performance.
Assembly of fl ue pipe with top outlet
The product is assembled for a top outlet as standard.
Fig. 22
1. Fit the gasket to the bottom end of the fl ue pipe.
2. Insert the fl ue pipe into the top plate.
Flue pipe
Gasket