Télécharger Imprimer la page

Dal Zotto WANNA IDRO Manuel Utilisateur page 46

Publicité

Les langues disponibles
  • FR

Les langues disponibles

GENERAL MENU
2
1
1
2
3
3
SET POWER
SET TEMPERATURE
USER MENU
SET CHRONO
STATUS
SETTINGS
** MENU
TECHNICIAN
GENERAL WARNINGS
Advice to follow for the rst start-ups of the product:
During the rst hours of operation, there may be some smoke or
odours, but they are due to the normal "thermal break-in" process.
During this process, the duration of which changes depending on
the product, it is recommended to:
Š Ventilate the room well
Š If present, remove any majolica parts from the top of the
product
Š Activate the product at the maximum power and temperature
Š Avoid remaining in the room for a long time
Š Do not touch the surfaces of the product
Notes:
The process is completed after a few heating/cooling cycles.
Do not use for the combustion of elements or substances other than
those indicated in the manual.
The company has an optional additional board that allows the boiler the following further functions when managing the system.
The table below indicates the various possibilities that the optional can o er.
DHW Storage Management
Pu er Management
3 heating areas
Instant DHW option
Pu er pump or 4th heating area management
Anti-legionella management for DHW storage
DHW storage chrono management
Auxiliary output management and control
46
4
6
6
4
OFF
5
6
POWER
**STOVE STATUS
SET CLOCK
LANGUAGE
DISPLAY
STAND BY
1
Go back - exit
2
3
4
5
5
Con rm - access Menu
6
ENABLE CHRONO
ENABLE PRG1
ENABLE PRG2
ENABLE PRG3
ENABLE PRG4
START PRG1
STOP PRG1
MONDAY PRG1...
...SUNDAY PRG1
SET PRG1
SAME STEPS FOR THE OTHER ONES
3 TIME SLOTS
Before turning on the product, it is necessary to perform the
following checks:
Š If it is intended to be connected to a hydraulic system, it must
be complete and fully functional and in compliance with
the instructions given in the product manual and with the
relevant regulations in force.
Š The pellet hopper must be completed loaded
Š The combustion chamber and the burn pot must be clean
Š Make sure that the re holder, the ash pan and the pellet
hopper close hermetically (if present in the hermetic version);
they must be closed and there must be no foreign bodies in
the sealing elements and gaskets.
Š Check that the power cord is properly connected
Š The bipolar switch (if present) must be set to position "1".
ENGLISH
Parameter scrolling: next (2) ; previous (3)
Modify settings data: increase (4); decrease (5)
*ENABLE V1
* AIR V1
RESET
PELLET %
* WHERE PRESENT
** RESERVED TO THE
TECHNICIAN
ROOM AIR TEMP SET
SET H2O
p
p
p
p
p
p
p
p

Publicité

loading