6. Hang the panel by letting the knobs through the eyes in the wall mounting bracket. Slide the panel as far as
possible to the right side and lower it as far as possible. Now the panel is mounted securely.
7. To remove the panel from the wall, you must lift and slide in the opposite direction, until the knobs are in
front of the eyes again. Now you can take the panel off.
Note: Guide the electric cable immediately downwards and make sure that it does not come into contact with
the panel. Do not conceal the cable behind the heater!
OPERATION
Plug the appliance into an appropriate electrical outlet. Turn on the appliance by pressing the power switch to
position "I". The power indicator light will be illuminated on the LED display. The appliance is standby.
You can use the control panel on the appliance or the separate remote control to operate your appliance.
Please note the control panel can only operate the basic functions. The remote control can operate the basic
functions as well as the advanced functions.
The remote control should be directed towards the LED display while using.
Basic functions:
1. Press the on/off button to turn on the appliance. Press the button again to turn the appliance off.
2. Set the temperature.
1) Press the button " + " or " - " to set your desired temperature. You can choose from 0-37℃. Long
pressing for rapid adjustment.
2) The LED display will flash the set temperature approx. 10 seconds and then turn back to show the
current temperature. It means the temperature has been set.
3) If the set temperature is higher than the current temperature, the appliance will start to heat and the
heating symbol will be illuminated on the LED display. If the set temperature is reached, the appliance
will automatically switch off and then switch on again when the room cools down. The heating symbol
will be off and illuminated again accordingly.
Note: If no button is pressed in approx. two minutes, the current temperature will disappear from the LED
display. Pressing any button will make the current temperature re-appear.
- 6 -