PARAMETER LEVEL
▸ Setting the operating parameters
Activate parameter level
Press this key to activate the parameter level. After approx. 3 seconds, the display shows "P01" for the
first parameter. When the key is pressed again, the corresponding parameter value is displayed and can
then be changed. In this way, all available parameters are selected one after the other.
Selecting the decade
Pressing this key advances the decade by one digit from left to right.
The selected, changeable decade flashes on the display.
Change value
With this key, the value in the selected decade is always increased by 1 (0...9 or 0/1).
Change sign
With this key, the sign of some parameters can be changed. (A negative sign is only possible if the value
is not equal to ZERO)
Exit parameter level
When leaving the parameter level, all parameters are saved in the internal flash memory in a zero-voltage-
safe manner.
for approx. 3 seconds/then press 1x each time
Press 1x
Press 1x
Press for approx. 3 seconds in the parameter level.