8
Fill level display
9
Knurled screw
10
Trigger safety catch
11
Mouth
12
Face plate
13
Quick clamp lever for face plate
14
Oil container with compressed air
special oil
15
Protective goggles
16
Nails
17
Staples
z Technical specifications
Dimensions
(W x H x D)
Weight
(without fasteners)
Type of trigger
Maximum permitted
pressure
(Working pressure)
Recommended
pressure range
Air consumption
depending on the
fastening operation
Recommended
lubricant
Loading capacity
Nail lengths
Staple length
Staple width
Recommended hose
diameter (internal)
8
GB/IE/NI/CY/MT
240 x 239 x 57 mm
1197 g
Compressed air
max. 8 bar
4 – 7 bar
approx. 0.09 l
Compressed air
special oil
100 pcs.
15 mm, 20 mm,
25 mm, 30 mm,
32 mm, 35 mm,
38 mm, 40 mm,
45 mm, 50 mm
10 – 40 mm
5.7 mm
9 mm
Compressed air
quality
Noise and vibration
information
Measured value determined
in accordance with EN
12549:1999, EN ISO 4871.
Typical A-weighted sound
pressure level of the device is:
92.7 dB(A)
Uncertainty K = 2.5 dB
L
: 105.7 dB(A)
WA
L
(at the work station): 98.8 dB(A)
pA
L
: 115.3 dB(C)
pC
These values are device-related
characteristic values and do not
reflect the noise emission at the
place of use. The noise emission
at the place of use depends,
for example, on the working
environment, the workpiece, the
workpiece support, the number of
fastening operations. Depending
on the work station conditions
and the shape of the workpiece,
it may be necessary to implement
customised noise reduction
measures, such as, for example,
placing the workpieces on
sound-absorbing mats, preventing
vibration of the workpieces by
clamping or covering, adjusting
clean,
oil-atomised and
condensate-free