Télécharger Imprimer la page

Danby DPTA070HEB2WDB Manuel Du Propriétaire page 21

Publicité

Les langues disponibles

Les langues disponibles

CARE & MAINTENANCE
CLEANING
To avoid possible electric shock, ensure that the appliance is unplugged before performing any cleaning or
maintenance.
The outside of the appliance can be wiped clean with a soft cloth or with a lukewarm, damp cloth if
necessary.
Do not use gasoline, benzene, thinner or any other chemicals to clean this appliance as these substances
can cause damage to the finish and deformation of plastic parts.
Never pour water directly onto the appliance as this will cause deterioration of electrical components and
wiring insulation.
ERROR CODES
If any of the below error codes appear on the display, unplug the appliance and then plug it back in. If the
error code persists, call for service.
E0 - failure of EEPROM parameter
E3 - fan stall error
E4 - Main control and display communication error
AS - room temperature sensor error
ES - evaporator temperature sensor error
CS - condenser temperature sensor error
OS - outside temperature sensor error
HS - exhaust temperature sensor error
LE - wire controller error
LO - room temperature is lower than 0°C / 32°F
HI - room temperature is higher than 37°C / 99°F
FP - low temperature protection
Control Codes (on some models)
LC - pad(s) on the control panel are not available. The appliance can only be set by using the remote
control.
FC - pad(s) on the control panel and remote control are not available. The appliance can be set using
FRONT DESK CONTROL only.
20

Publicité

loading

Ce manuel est également adapté pour:

Dpta090heb2wdbDpta120heb2wdbDpta150heb2wdb