Illustration
On removing the flat-fold filter, cover
the same immediately with the en-
closed bag and close it.
Order no. bag: 6.277-454.0
Dispose off the used flat-folded filter in
a dust-tight bag according to the statu-
tory provisions.
Remove the dirt that has accumulated
on the pure air side.
Insert new flat-folded filter.
Close the filter door, it must lock into
place.
Fasten the screw of the filter cover us-
ing the screwdriver in the clockwise di-
rection.
Replacing the safety filter sack
Danger
The dust that has been collected should be
transported in dust-proof containers. No refill-
ing is permitted. The waste containing as-
bestos is to be disposed off according to the
rules and regulations for waste disposal.
Danger
Only persons trained in waste disposal are
permitted to dispose off the dust collection
container.
Illustration
Close the suction connection, see wet vac-
uuming.
Release and remove the suction head.
Illustration
Pull over the safety filter sack.
Illustration
Pull out the safety sheet.
Close the safety filter sack using the self-ad-
hesive flap.
Pull the safety filter sack towards the rear.
Illustration
Close tightly the opening of the suction con-
nection of the safety filter sack using the
closing lid.
Illustration
Securely close the safety filter bag with the
attached cable tie.
Remove the safety filter bag.
Wipe the inside of the container using a
damp cloth.
Dispose of the safety filter bag in a dust-
tight bag according to the statutory pro-
visions.
Illustration
Affix a new safety filter bag.
Illustration
Pull the safety filter sack over the con-
tainer.
Insert and lock the suction head.
Cleaning the electrodes
Release and remove the suction head.
Clean the electrodes with a brush.
Insert and lock the suction head.
Troubleshooting
Danger
First pull out the plug from the mains before
carrying out any tasks on the machine.
Note:In case of a failure (e.g. filter break-
age) the appliance must be turned off im-
mediately. The failure must be remedied
before the appliance is put into operation
again.
Suction turbine does not run
Check cables, plugs, fuse, socket and
electrodes.
Turn on the appliance.
Suction turbine turns off
Empty the container.
Suction turbine does not start again
after the container has been
Turn off the appliance and wait for 5
seconds, turn it on again after 5 sec-
onds.
Clean the electrodes as well as the
space between the electrodes with a
brush.
7
-
EN
emptied
23