Start up
The appliance allows 2 operating modes:
1 Industry vacuum cleaner mode (socket
not used)
2 Dedusting mode (socket used)
Connect the suction hose and insert in-
sert the suction nozzle or connect to the
dust-generating device depending on
the operating mode.
Warning
Do not vacuum without the filter elements;
otherwise, the suction motor can get dam-
aged and this can be hazardous to health
on account of increased release of fine dust
particles.
The horn blows when the air speed falls be-
low 20 m/s.
Note: The horn reacts to negative pressure.
Set the rotary switch to the correct suc-
tion hose cross-section.
Anti-static system
Static charge is deflected by providing
earthing to the connection nozzles. This
prevents the formation of sparks and cur-
rent shocks due to attachments (option)
with electrical conductivity.
Dry vacuum cleaning
The appliance is equipped with a paper
–
filter bag fitted with locking lid.
Order No. Safety filter sack: 6.904-
264.0 (5 pieces)
Note:You can use this appliance to take up
all types of dust up to dust class H. It is stat-
utorily necessary to use a dust collection
bag (see Filter systems for order number).
Note: The appliance is suited as industrial
vacuum cleaner and as dedusting device
for the mobile operation to take up dry, non-
combustible dusts with MAK values.
Unused flat-fold filters may only be
–
stored and transported in the packaging
(carton).
Illustration
The lamella of the flat-fold filter should
–
not be touched during installation.
Horn
Warning
The flat-fold filter and the safety filter sack
must never be removed during the dust ex-
traction process.
Installing the safety filter sack
Release and remove the suction head.
Illustration
Insert the safety filter sack.
Illustration
Pull the safety filter sack over the container.
Insert and lock the suction head.
Wet vacuum cleaning
Danger
No dusts hazardous to health should be
sucked in during wet vacuuming.
Inserting the rubber lips
Illustration
Remove the brush strips.
Install the rubber lips.
Note: The structured side of the rubber lips
must point outwards.
Close the suction connection
Illustration
Properly insert the connection socket in
the suction connection.
Push in the connection socket until it
locks into place.
Turn the suction connection with the
connection socket to the right to close it
tightly.
Note: The accurate fit is ensured by means
of a "bayonet connection".
Removing the safety filter sack
Release and remove the suction head.
Illustration
Pull over the safety filter sack.
Illustration
Pull out the safety sheet.
Close the safety filter sack using the self-ad-
hesive flap.
Pull the safety filter sack towards the rear.
Illustration
Close tightly the opening of the suction
connection of the safety filter sack using
the closing lid.
3
-
EN
19