Télécharger Imprimer la page

Kärcher NT 45/1 Tact Te H Manuel D'utilisation page 20

Masquer les pouces Voir aussi pour NT 45/1 Tact Te H:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 27
Illustration
 Securely close the safety filter bag with
the attached cable tie.
 Remove the safety filter bag.
 Wipe the inside of the container using a
damp cloth.
 Dispose of the safety filter bag in a dust-
tight bag according to the statutory pro-
visions.
 Insert and lock the suction head.
To suck wet dirt, always remove the
safety filter bag.
General
Warning
The flat pleated filter must must always be
in place while vacuuming.
If wet dirt is vacuumed with the uphol-
stery or crevice nozzle, or if water is
sucked up from a container, it is recom-
mended to deactivate the "automatic fil-
ter cleaning" function.
If the maximum liquid level is reached
the appliance will turn off automatically.
In case of non-conductive liquids
(such as emulsion drilling fluids,
oils, and greases) the appliance is
not turned off when the container is
full. The filling level must be continu-
ously monitored and the container
must be emptied in time.
After the wet vacuuming: Clean the flat
folded filter with the filter cleaning.
Clean the electrodes with a brush.
Clean the container with a damp rag
and dry it.
Clip connection
Illustration
The suction hose is equipped with a clip
system. All C-35/C-DN-35 accessories can
be connected.
20
Turning on the Appliance
 Plug in the main plug.
 Switch on the appliance at the main
switch.
Adjust the suction output
 Set the suction output (min - max) at the
rotary switch.
Working with electrical power tools
Danger
Risk of injury and damage! The socket out-
let is only for the connection of power tools
to the vacuum cleaner. Any other use of the
socket outlet is not permitted.
 Connect the mains plug of the electric
power tool to the vacuum cleaner.
 Switch on the appliance at the main
switch.
Indicator lamp is on; vacuum cleaner is in
the standby mode.
Note: The vacuum cleaner is turned on and
off automatically with the electric power tool.
Note: The vacuum cleaner starts automat-
ically within 0.5 seconds and continues to
run for 15 seconds after the power tool has
being switched off.
Note: Please refer to "Technical specifica-
tions" for the power connection specifica-
tions of the power tools.
Illustration
 Adjust the stepped power tool adaptor
to fit the connection of the electric pow-
er tool.
Illustration
 Remove the elbow from the suction
hose.
 Attach the stepped power tool adaptor
to the suction hose.
Illustration
 Connect the adaptor to the electric pow-
er tool.
Note: The different suction hose sections
are required to allow an adjustment to the
connection sections of the processing
tools.
4
-
EN
Operation

Publicité

loading