en
Fill descaler
Press start
● Pour lukewarm water into the empty
water tank (17) up to the 0.5 l mark and
then dissolve 1 Siemens descaling tablet
TZ80002 in it� When using TZ60002,
2 tablets must be dissolved�
● Press the start button (10)�
Place container
Press start
● Place a receptacle with a capacity of at
least 1 litre under the outlet (6a)�
● Press the start button (10)�
Calc'n'Clean in progress
The descaling pro gramme will now run for
about 22 minutes�
Clean / Fill water tank
Press start
● Rinse the water tank (17) and refill it with
fresh water up to the max mark�
● Press the start button (10)�
Calc'n'Clean in progress
The descaling pro gramme now runs for
about 10 minutes and rinses the appliance�
Empty drip tray
Insert drip tray
● Empty drip tray (8) and replace them�
Replace the filter if one is being used. The
appliance has finished cleaning is ready for
use again�
Important: Wipe down the appliance using
a soft, damp cloth to immediately remove
any descaler residue� Such residue can
cause corrosion� New sponge cloths may
contain salts. Salts can cause rust film
on stainless steel and must therefore be
washed out thoroughly before use�
18
All manuals and user guides at all-guides.com
Frost protection
A To avoid damage from low
Note: The appliance must be ready for use
and the water tank (17) filled.
● Place a large receptacle under outlet (6a)�
● Press the l / m button (12) and
● Switch the appliance off at the power
● Empty the water tank (17) and the
Accessories
The following accessories can be obtained
from retailers and customer service�
Accessories
Cleaning tablets
Descaling tablets
Water filter
Care set
Milk container with
"Fresh Lock" lid
temperatures during transport and
storage, the appliance must be
completely emptied first.
allow the appliance to steam for about
15 seconds�
on/off switch O / I (9)�
drip tray (8)�
Ordering number
Retail /
Customer service
TZ60001 / 00310575
TZ80002 / 00576693
TZ70003 / 00575491
TZ80004 / 00576330
TZ80009N / 00576166