MAINTENANCE
CLEANING
BEFORE CLEANING THE APPLIANCE ALWAYS TURN IT OFF AND DISCONNECT FROM POWER
SUPPLY AND WAIT UNTIL IT HAS COOLED DOWN.
PLEASE MAKE SURE NOT TO REMOVE THE GREASE ON THE HINGES. IF THE GREASE NEEDS
TO BE REPLENISHED, WE SUGGEST TO USE THE LOCTITE 8104 GREASE OR OTHER FOOD SAFE
ALTERNATIVES.
SURFACES THAT ARE STILL HOT CAN BE DAMAGED IF THEY COME INTO CONTACT WITH COLD
WATER OR A DAMP CLOTH.
NEVER USE ABRASIVE, CORROSIVE OR CHLORINE BASED CLEANING PRODUCTS. NEVER USE
STEEL OR PLASTIC SCOURING PADS. NEVER LEAVE DEPOSITS OF ACID OR ALKALINE SUBSTANCES
(VINEGAR, SALT, LEMON JUICE ETC.) ON THE APPLIANCE. STAINLESS STEEL OR ENAMELLED
SURFACES MUST BE CLEANED ONLY WITH WATER AND SOAP OR A NEUTRAL DETERGENT,
THOROUGHLY RINSE AND DRY. USE CLEAN SPONGES OR CLOTHS TO CLEAN.
INJECTORS
CLEANING OR REPLACING GAS INJECTORS MUST ONLY BE PERFORMED BY AUTHORISED AND
QUALIFIED GAS SERVICE ENGINEERS. THE MANUFACTURER DECLINES ALL RESPONSIBILITY IN
REGARD.
When removing and mounting the injectors the injector holder must be must be held in place with the aid of a tool
(FIG. 5 - PAG. 144).
BURNER
AUXILIARY
Ø 47 mm
SEMI-RAPID
Ø 62 mm
RAPID
Ø 77 mm
TEST PRESSURE POINT
THE TEST PRESSURE POINT (PRESSURE CHECK VALVE) IS FITTED UNDER THE HOB. (FIG. 4 - PG. 143).
Removing and mounting this test pressure point (pressure check valve) must be performed by a qualified gas service
engineer. Gas pressure is related to the type of gas used to supply the appliance. Refer to chapter GAS in this manual.
Ø INJECTOR (mm)
0,50
0,45 ( MOD. PI7903T - PI7923T )
0,67
0,64 ( MOD. HBH1303ILG/IRG )
0,75
(IF FITTED)
STAMPED N.
50
45 ( MOD. PI7903T - PI7923T )
67
64 ( MOD. HBH1303ILG/IRG )
75