DECLARATION OF CONFORMITY
This product is marked
2006/95/CE
– Low voltage no.
– Electromagnetic compatibility no. 89/336 ECC, 92/31 EEC
and 93/68 EEC.
This declaration will become void in case of misuse and/or non
observance though partial of manufacturer's installation and/or
operating instructions.
F-GAS Regulation (EC) No. 842/2006
Do not vent R410A into atmosphere: R410A is a fluorinated
greenhouse gas, covered by Kyoto Protocol, with a Global
Warming Potential (GWP) = 1975.
OPERATING LIMITS
L
Cooling Maximum conditions
Outdoor temperature : 43°C D.B.
Room temperature
: 32°C D.B. / 23°C W.B.
L
Cooling Minimum conditions
Outdoor temperature : 19°C D.B.
Room temperature
: 19°C D.B. / 14°C W.B.
L
Heating Maximum conditions
Outdoor temperature : 24°C D.B. / 18°C W.B.
Room temperature
: 27°C D.B.
L
Heating Minimum conditions
Outdoor temperature :
Room temperature
: 16°C D.B.
WARNING
Read the yellow instruction sheet attached to the outdoor
units.
PARTS
FIGURE
Remote
control
Remote control
unit holder
AAA Alkaline
battery
Screw
M5 x 30
as it satisfies Directives:
.
–15°C W.B.
ACCESSORIES SUPPLIED WITH THE UNIT
Q.TY
PARTS
Tapping
1
screw 4x30
1
Drain cap *
2
Raw plug *
4
37.4163.333.0
INSTALLATION INSTRUCTIONS
- Split system air conditioner -
This air conditioner uses the new refrigerant R410A
Model Combinations
Combine indoor and outdoor units only as listed below.
Indoor Units
CAF97R5I
CAF127R5I
CAF187R5I
FOR "MULTI SPLIT" INSTALLATION SEE
CAF98MR5I
"MULTI DC INVERTER COMBINATIONS
TABLE"
CAF128MR5I
Power Supply:
220 - 240 V ~ 50 Hz
Tools required for installation (not supplied)
1. Standard screwdriver
2. Phillips head screwdriver
3. Knife or wire stripper
4. Tape measure
5. Level
6. Sabre saw or key hole saw
7. Hacksaw
8. Core bits ø 5
FIGURE
Q.TY
2
4
2
10/2007
Outdoor Units
GRF97R5I
GRF127R5I
GRF186R5I
19. Hammer
10. Drill
11. Tube cutter
12. Tube flaring tool
13. Torque wrench
14. Adjustable wrench
15. Reamer (for reburring)
16. Hex. key
PARTS
FIGURE
Full scale
diagram
Drain
elbow *
Cushion
rubber *
*
Packed in the outdoor unit.
EG
I
F
D
E
P
GR
Q.TY
1
1
4