COOLING ONLY MODELS
OPERATING LIMITS
í Maximum conditions
Outdoor temperature : 52¡C D.B.*
Room temperature
: 35¡C D.B. / 22.5¡C W.B.
í Minimum conditions
Outdoor temperature : 19¡C D.B.**
Room temperature
: 19¡C D.B. / 14¡C W.B.
í Model name GRxxxL - GRVxxxL
*: 50¡C D.B. **: Ð15¡C D.B.
HEAT PUMP MODELS
OPERATING LIMITS
í Cooling Maximum conditions
Outdoor temperature : 46¡C D.B.
Room temperature
: 35¡C D.B. / 22¡C W.B.
í Cooling Minimum conditions
Outdoor temperature : 19¡C D.B.
Room temperature
: 19¡C D.B. / 14¡C W.B.
í Heating Maximum conditions
Outdoor temperature : 24¡C D.B. / 18¡C W.B.
Room temperature
: 27¡C D.B.
í Heating Minimum conditions
Outdoor temperature : Ð8¡C D.B. / Ð9¡C W.B.
COOLING ONLY MODEL KPAV128C5
OPERATING LIMITS
í Maximum conditions
Outdoor temperature : 43¡C D.B.
í Minimum conditions
Outdoor temperature : 19¡C D.B.*
í Model name GRxxxL-GRVxxxL
*Ð15¡C D.B.
HEAT PUMP MODEL KPA128R5-KPAV128R5
OPERATING LIMITS
í Cooling Maximum conditions
Outdoor temperature : 43¡C D.B.
Room temperature
: 32¡C D.B. / 23¡C W.B.
í Cooling Minimum conditions
Outdoor temperature : 19¡C D.B.
Room temperature
: 19¡C D.B. / 14¡C W.B.
í Heating Maximum conditions
Outdoor temperature : 24¡C D.B. / 18¡C W.B.
Room temperature
: 27¡C D.B.
í Heating Minimum conditions
Outdoor temperature : Ð8¡C D.B. / Ð9¡C W.B.
Tools required for installation (not supplied)
1. Standard screwdriver
2. Phillips head screwdriver
3. Knife or wire stripper
4. Tape measure
5. Level
6. Sabre saw or key hole saw
7. Hacksaw
8. Core bits ¿ 5
01/2000
All manuals and user guides at all-guides.com
Room temperature : 32¡C D.B. / 23¡C W.B.
Room temperature : 19¡C D.B. / 14¡C W.B.
9. Hammer
10. Drill
11. Tube cutter
12. Tube flaring tool
13. Torque wrench
14. Adjustable wrench
15. Reamer (for reburring)
INSTALLATION INSTRUCTIONS
-
Floor or celling mounted split units
DECLARATION OF CONFORMITY
This product is marked
Ð Low voltage no. 73/23 EEC and 93/68 EEC.
Ð Electromagnetic compatibility no. 89/336 ECC, 92/31 EEC
and 93/68 EEC.
This declaration will become void in case of misuse and/or non
observance though partial of manufacturer's installation and/or
operating instructions.
Model Combinations
Combine indoor and outdoor units only as listed below.
COOLING ONLY MODELS R22
Indoor Units
KPAV128C5
KPAV185C5
KPAV225C5
HEAT PUMP MODELS R22
Indoor Units
KPA128R5
KPAV184R5
KPAV224R5
COOLING ONLY MODELS R407C
Indoor Units
KPAV128C5
KPAV185C5
KPAV225C5
HEAT PUMP MODELS R407C
Indoor Units
KPAV128R5
KPAV184R5
KPAV224R5
Power Supply:
The last digit(s) of the model number indicates the required
power supply to the unit.
5: 220 - 240 V ~ 50 Hz / 7: 380-400 V - 3N ~ 50 Hz
Last digit(s) of the model number
SKP-C/SKP-R
as it satisfies Directives:
Outdoor Units
GR129C5
GR127L5
GR185C5
GR185C7
GR226C5
GR226C7
Outdoor Units
GR129R5
GR184R5
GR224R5
Outdoor Units
GRV127L5
GRV185C5
GRV185C7
GRV185L5
GRV185L7
GRV226C5
GRV226C7
Outdoor Units
GRV127R5
GRV184R5
GRV224R5
10 11 306 F.GB.I.E.D.03
-
EG
I
F
D
E