Installation site selection - Indoor unit
AVOID
• Direct sunlight.
• Nearby heat sources that may affect unit performance.
• Areas where leakage of flammable gas may be expected.
• Locations where large amounts of oil mist may occur (such as in kitchen
or near factory equipment) because oil contamination can cause
operation problems and may deform plastic surfaces and parts of the
unit.
EG
• Unsteady locations that will cause noise or possible water leakage.
• Locations where the remote control unit will be splashed with water or
affected by dampness or humidity.
• To make holes in areas where electrical wiring or conduits are located.
• To place appliances under tension (household appliances, computers),
because in case of emergency operation the unit could drip condensate
water.
ADDITIONAL MATERIAL REQUIRED FOR INSTALLATION (NOT SUPPLIED)
Deoxidized annealed copper tube for refrigerant tubing connecting the units of the system; it has to be insulated with foamed polyethylene
(min. thickness 8mm).
MODEL
CAF97/127-98/128
CAF187
PVC pipe for condensate drain pipe (ø int.18mm) in lenght suitable to let the condensate flow into the outside drainage.
Anti-freeze oil for flare connections (about 30g.).
Electric wire: use insulated copper wires of size and length as shown in the table "ELECTRICAL DATA" and at paragraph "SYSTEM WIRING
DIAGRAMS".
TUBING LENGTH AND ELEVATION DIFFERENCE LIMITS
MODEL
CAF97/127
CAF187
FOR "MULTI SPLIT" INSTALLATION SEE OUTDOOR UNIT INSTALLATION INSTRUCTIONS
* For every meter of tube more than standard lenght at shipment, add refrigerant as shown in the table. No additional charge of compressor
oil is necessary.
NARROW TUBE
OUTER DIAMETER
6,35 mm
6,35 mm
MAX. ALLOWABLE
TUBING LENGTH AT
SHIPMENT
(m)
7,5
10
DO
• Select an appropriate position from which every corner of the room
can be uniformily cooled.
• Select a sufficiently strong ceiling to support the weight of the unit.
• Select a location where tubing and drain hose have the shortest run
to the outside.
• Allow access for operation and maintenance as well as unrestricted air
flow around the unit.
Installation site selection - Outdoor unit
AVOID
• Heat sources, exhaust fans.
• Direct sunlight.
• Damp, humid or uneven locations.
• To make holes in areas where electrical wiring or conduits are located.
DO
• Choose places as cool as possible and well ventilated.
• use lug bolts or equal to bolt down the unit, reducing vibration and
noise.
MIN. THICKNESS
OUTER DIAMETER
0,8 mm
0,8 mm
LIMIT OF TUBING
LIMIT OF ELEVATION
LENGTH
(m)
15
30
4
LARGE TUBE
MIN. THICKNESS
9,52 mm
12,7 mm
REQUIRED AMOUNT OF
DIFFERENCE
ADDITIOONAL
H
REFRIGERANT
(m)
7
7
0,8 mm
0,8 mm
(g / m)*
a) 15
b) 25
(go on page 5)