DECLARATION OF CONFORMITY
This product is marked
– Low voltage no. 73/23 EEC and 93/68 EEC.
– Electromagnetic compatibility no. 89/336 ECC, 92/31 EEC and 93/68 EEC.
This declaration will become void in case of misuse and/or non observance though partial of manufacturer's installation and/or
operating instructions.
OPERATING LIMITS
í Cooling Maximum conditions
Outdoor temperature : 43°C D.B.
Room temperature
: 32°C D.B. / 23°C W.B.
í Cooling Minimum conditions
Outdoor temperature : 19°C D.B.
Room temperature
: 19°C D.B. / 14°C W.B.
í Heating Maximum conditions
Outdoor temperature : 24°C D.B. / 18°C W.B.
Room temperature
: 27°C D.B.
í Heating Minimum conditions
Outdoor temperature : –8°C D.B. / –9°C W.B.
Power Supply:
220 - 240 V ~ 50 Hz
ACCESSORIES SUPPLIED
WITH THE UNIT
PARTS
FIGURE
Q.TY
REMOTE
1
CONTROL UNIT
TWIN WIRE CABLE
1
DRAIN
1
ELBOW
*
*
Available only for heat
pump models.
All manuals and user guides at all-guides.com
as it satisfies Directives:
37.4163.230.0
INSTALLATION INSTRUCTIONS
- Split system air conditioner -
Model Combinations
Combine indoor and outdoor units only as listed below.
Indoor Units
MCAF72R5TAA
MCAF92R5TAA
MCAF122R5TAA
Tools required for installation (not supplied)
1. Standard screwdriver
2. Phillips head screwdriver
3. Knife or wire stripper
4. Tape measure
5. Level
6. Sabre saw or key hole saw
7. Hacksaw
8. Core bits ø 5
02/2004
Outdoor Units
GRF74R5TAA
GRF74C5TAA
GRF94R5TAA
GRF94C5TAA
GRF124R5TAA
GRF124C5TAA
19. Hammer
10. Drill
11. Tube cutter
12. Tube flaring tool
13. Torque wrench
14. Adjustable wrench
15. Reamer (for reburring)
16. Hex. key
EG
I
F
D
E