Warning on Refrigerant R290
The unit is designed only for use with R290 (propane) gas as the designated
refrigerant.
THE REFRIGERANT LOOP IS SEALED. ONLY A QUALIFIED TECHNICIAN SHOULD ATTEMPT TO
SERVICE!
The lack of smell does not indicate a lack of escaped gas.
No open flames, cigarettes or other possible sources of ignition should be used in the
vicinity of the unit.
Component parts are designed for propane and non-incentive and non-sparking.
Component parts shall only be replaced with identical repair parts.
THE UNIT MAY ONLY BE INSTALLED IN A ROOM WITH A MINIMUM FLOOR AREA OF 4 m².
R290 is a flammable gas that is heavier than air. On this basis, if the gas leaks from the
unit, the concentration will be the highest at ground level. However, the gas can be
lifted (e.g. by draft, fan, etc.) to higher levels. The R290 (propane) used in this unit has
no odor.
Do not use the unit in a room with an open flame, other high-level heat sources (e.g.
cigarettes, candles, etc.) or electrical discharges. Install the unit in a room which can
be ventilated when necessary and where gas accumulation is not possible.
If R290 (propane) is detected in the room, or a leak is suspected, do not allow
unauthorized persons to search for the source of the leak. In such cases, evacuate
all people from the room, open the windows, leave the room and notify your local fire
department to advise them that a propane leak has occurred. Do not allow any person
to return to the room until the commanding officer of the fire department or a certified
service engineer decides that the risk has ceased to exist.