INSTALLATION

En

Location selection

Location of a water treatment system is important. The following conditions are required :
Level platform or floor.
Room to access equipment for maintenance and adding regenerant (salt) to tank.
Ambiant temperatures over 34°F (1°C) and below 120°F (49°C).
Water pressure below 120 psi (8.27 bar) and above 20 psi (1.4 bar).
Constant electrical supply to operate the controller.
Total minimum pipe run to water heater of ten feet (three meters) to prevent
backup of hot water into system.
Local drain for discharge as close as possible.
Water line connections with shutoff or bypass valves.
Must meet any local and state codes for site of installation.
Valve is designed for minor plumbing misalignments. Do not support weight of
system on the plumbing.
Be sur all soldered pipes are fully cooled before attaching plastic valve to the
plumbing.

Water line connection

A by-pass valve system should be installed on all water conditioning systems.
Bypass valves isolate the conditioner from the water system and allow unconditioned
water to be used. Service or routine maintenance procedures may also require that
the system is bypassed. Figure 1 and 2 show the three common bypass methods.
256 By-pass for use
with 255 valve body.
Typical globe valve
Figure 1
Figure 2
by-pass system
In
Out
Normal operation
Water
conditioner
Normal
In by-pass
operation
6
In
Out
In by-pass
Water
conditioner